infrared radiant heaters Patented 2 Stage low-intensity tube heaters provide precise matching of air/gas flows at both high and low fire stages. True Dual heaters maintain precise control at a desired comfort level while reducing energy costs without “overshooting”. 2-Stage - True Dual Stainless Steel Heaters
LENGTH (Overall Length including the burner)
Straight Tubes
BTUH’S X 1,000 Low/High
Gas Type N or L N or L N or L N or L
20’ (22’)
30’ (32’)
40’ (42’)
50’ (52’)
60’ (62’)
70 (72’)
S M T S
85/65
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A N/A
X
100/65 125/95 150/100 175/125 200/145
N/A N/A
N/A
X X
X X X
X X X X
N/A N/A
X X X
Part # Breakdown for Ordering 2 Stage Heaters System Type-BTU Input(Gas Type)Length Example: SMTS-85/65-N20
N
N/A
N/A
X
X X
N or L
N/A N/A N/A
LENGTH (Overall Length including the burner)
U-Tubes
BTUH’S X 1,000 Low/High
Gas Type N or L N or L N or L N or L N or L N or L
20’ (13’6”)
30’ (18’6”)
40’ (23’6’)
50’ (28’6”)
60’ (33’6”)
70 (38’6”)
S M T U
System Information
40/60 65/85
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A
X X
Manifold Operating Pressure Natural Gas & LP/Propane: 5” WC Minimum Inlet Pressure Natural Gas: 7” WC LP/Propane: 11” WC
65/100 105/120 130/150 150/200
N/A
N/A
X
X X X
N/A N/A N/A N/A
X X X
N/A N/A N/A
X
X
Single Stage - Stainless Steel Heaters Single Stage low-intensity tube heaters operate at one stage for maximum effectiveness in high heat loss situations.
1/2 ” FPT Gas Inlet Electrical Rating:
LENGTH (Overall Length including the burner)
120 VAC-60 Hz-1 Phase Blower: 1/24 h.p. Motor 2.3 max. amp. draw @ 138 cfm/free air Vent Size: 4” ID
Straight Tubes
BTUH’S 1000
Gas Type
20’ (22’)
30’ (32’)
40’ (42’)
50’ (52’)
60’ (62’)
70 (72’)
Series
S S T G
40-60 65-85
A N or L MB N or L B N or L B N or L C N or L C N or L
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
X X
Part # Breakdown for Ordering 1 Stage Heaters System Type-BTU Input-Length(Series) (Gas Type) Example: SSTS-60-20AL
65-100 105-120 130-150 150-200
N/A
N/A N/A N/A
X
X X
N/A N/A
N/A N/A N/A N/A
X X X
N/A N/A N/A N/A N/A N/A
X
X
LENGTH (Overall Length including the burner)
U-Tubes
Please see page 52 for accessories
BTUH’S 1000
Gas Type
20’ (13’6”)
30’ (18’6”)
40’ (23’6’)
50’ (28’6”)
60’ (33’6”)
70 (38’6”)
Series
S S T U
High Elevation Areas: Elevation must be noted on the PO before submitting it to AMGDS. All units are available for higher elevations. Please consult the factory to determine if the unit size is available at a certain elevation.
40-60 65-85
A N or L MB N or L B N or L B N or L C N or L C N or L
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
X X
65-100 105-120 130-150 150-200
N/A
N/A N/A N/A
X
X X X
N/A N/A N/A N/A
N/A N/A N/A N/A
X X X
N/A N/A N/A
X
X
800-233-1487