infrared radiant heaters Patented 2 Stage low-intensity tube heaters provide precise matching of air/gas flows at both high and low fire stages. True Dual heaters maintain precise control at a desired comfort level while reducing energy costs without “overshooting”. 2-Stage - True Dual Stainless Steel Heaters

LENGTH (Overall Length including the burner)

Straight Tubes

BTUH’S X 1,000 Low/High

Gas Type N or L N or L N or L N or L

20’ (22’)

30’ (32’)

40’ (42’)

50’ (52’)

60’ (62’)

70 (72’)

S M T S

85/65

N/A N/A N/A

N/A N/A N/A

N/A N/A N/A N/A

X

100/65 125/95 150/100 175/125 200/145

N/A N/A

N/A

X X

X X X

X X X X

N/A N/A

X X X

Part # Breakdown for Ordering 2 Stage Heaters System Type-BTU Input(Gas Type)Length Example: SMTS-85/65-N20

N

N/A

N/A

X

X X

N or L

N/A N/A N/A

LENGTH (Overall Length including the burner)

U-Tubes

BTUH’S X 1,000 Low/High

Gas Type N or L N or L N or L N or L N or L N or L

20’ (13’6”)

30’ (18’6”)

40’ (23’6’)

50’ (28’6”)

60’ (33’6”)

70 (38’6”)

S M T U

System Information

40/60 65/85

N/A N/A N/A N/A N/A N/A

N/A N/A N/A N/A N/A

N/A N/A N/A N/A N/A

X X

Manifold Operating Pressure Natural Gas & LP/Propane:  5” WC Minimum Inlet Pressure Natural Gas: 7” WC LP/Propane: 11” WC

65/100 105/120 130/150 150/200

N/A

N/A

X

X X X

N/A N/A N/A N/A

X X X

N/A N/A N/A

X

X

Single Stage - Stainless Steel Heaters Single Stage low-intensity tube heaters operate at one stage for maximum effectiveness in high heat loss situations.

1/2 ” FPT Gas Inlet Electrical Rating:

LENGTH (Overall Length including the burner)

120 VAC-60 Hz-1 Phase Blower: 1/24 h.p. Motor 2.3 max. amp. draw @ 138 cfm/free air Vent Size: 4” ID

Straight Tubes

BTUH’S 1000

Gas Type

20’ (22’)

30’ (32’)

40’ (42’)

50’ (52’)

60’ (62’)

70 (72’)

Series

S S T G

40-60 65-85

A N or L MB N or L B N or L B N or L C N or L C N or L

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

X X

Part # Breakdown for Ordering 1 Stage Heaters System Type-BTU Input-Length(Series) (Gas Type) Example: SSTS-60-20AL

65-100 105-120 130-150 150-200

N/A

N/A N/A N/A

X

X X

N/A N/A

N/A N/A N/A N/A

X X X

N/A N/A N/A N/A N/A N/A

X

X

LENGTH (Overall Length including the burner)

U-Tubes

Please see page 52 for accessories

BTUH’S 1000

Gas Type

20’ (13’6”)

30’ (18’6”)

40’ (23’6’)

50’ (28’6”)

60’ (33’6”)

70 (38’6”)

Series

S S T U

High Elevation Areas: Elevation must be noted on the PO before submitting it to AMGDS. All units are available for higher elevations. Please consult the factory to determine if the unit size is available at a certain elevation.

40-60 65-85

A N or L MB N or L B N or L B N or L C N or L C N or L

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

X X

65-100 105-120 130-150 150-200

N/A

N/A N/A N/A

X

X X X

N/A N/A N/A N/A

N/A N/A N/A N/A

X X X

N/A N/A N/A

X

X