LGC AXIO Proficiency Testing - 2027 Catalogue

LGC AXIO Proficiency Testing Schemes 2027

Surface/Waste/Sludge/Bathing/Recreational/Natural Sample Code Matrix Analytes

PT-WT-416 Simulated Effluent Sludge PT-WT-419 Surface/Waste/ Bathing Water

10g simulated sludge sample

Detection of Salmonella species

Enumeration of total coliforms; faecal coliforms; Escherichia coli ; Enterococci (faecal streptococci); Detection of Salmonella species Total aerobic count; Enumeration of coagulase positive staphylococci; Staphylococcus species; sulphite-reducing Clostridia; Clostridium perfringens Enumeration of total coliforms; faecal coliforms; Escherichia coli ; Enterococci (faecal streptococci); Detection of Salmonella species

10ml vial to be reconstituted to final volume of up to 10 x 1 litre 10ml vial to be reconstituted to final volume of 1 litre 10ml vial to be reconstituted to final volume of up to 10 x 1 litre

PT-WT-421 Surface/Bathing/ Recreational Water

PT-WT-422 Sea Water

Enumeration of Enterococci; Escherichia coli ; Enterobacteriacae

PT-WT-432 Simulated Effluent Sludge PT-WT-435 Surface/Waste/ Recreational Water

10g simulated sludge sample

Enumeration of Escherichia coli ; Enterococci; Pseudomonas aeruginosa

10ml vial to be reconstituted to final volume of up to 10 x 1 litre

PT-WT-436 Waste water

Vial

Detection of Somatic coliphages; Quantification of Somatic coliphages

General water microbiology Sample Code Matrix

Analytes

PT-WT-426 General Water PT-WT-427- VIRTUAL PT-WT-434 Water (all types)

Vial

Identification of unknown organism

Paper exercise

Colony count and calculation of number of microorganisms

10ml vial to be reconstituted to final volume of up to 10 x 1 litre 10ml vial to be reconstituted to final volume of up to 10 x 1 litre

Detection of Salmonella species

Detection of Aeromonas species; Enumeration of Aeromonas species

PT-WT-437 General Water

Hospital/Pharmaceutical Sample Code Matrix

Analytes

PT-WT-429 Dialysis Water

10ml vial to be reconstituted to final volume of 100ml 10ml vial to be reconstituted to final volume of 1 litre

Total aerobic count @ 17-23˚C

PT-WT-433 Endoscope water

Total viable count; Detection of environmental Mycobacterium species; Pseudomonas aeruginosa

The full range and availability of test materials and analytes is determined on an annual basis and may be added or removed. For accredited and non-accredited status, plus the most up to date sample data, please see the current application form/scheme description for this scheme.

82 lgcstandards.com/AXIO-PT