xLadder user manual-V2.0.0.6

3.3 wiring xLogic

Wire the xLogic by using a screwdriver with a 3-mm blade.

You do not need wire ferrules for the terminals. You can use conductors

with cross-sections of up to the following thicknesses:

1 x 2.5 mm2

2 x 1.5 mm2 for each second terminal chamber

Tightening torque: 0.4.. .0.5 N/m or 3. ..4 lbs/in

Note

Always cover the terminals after you have completed the installation. To

protect xLogic adequately from impermissible contact to live parts, local

standards must be complied with.

3.4 Connecting the power supply

ThePR-12AC,PR-18AC, PR-24AC versions of xLogic are suitable for operation

with rated voltages of 110 V AC and 240 V AC. The PR-12DC,PR-18DC, PR-24DC

versions can be operated with a 12 or 24 VDC power supply.

Note

A power failure may cause an additional edge triggering signal.

Data of the last uninterrupted cycle are stored in

xLogic

19