BlueCool P-Series Twin chiller
Type
P60 T
P72 T
P84 T
P96 T
P120 T
Cooling capacity* (BTU/ h)
60,000
72,000
84,000
96,000
120,000
Cooling capacity* (kW)
17.6
21.1
24.6
28.1
35.2
Frequency (Hz)
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
Current draw running** (A) for 230 V 1-phase
14
16
19
25
–
Current draw running** (A) for 400 V 3-phase
5.8
7.1
8.1
10
12
Current draw running** (A) for 208 V 3-phase
10
12
14
17
33
Current draw running FLA**** (A) for 230 V 1-phase Current draw running FLA**** (A) for 400 V 3-phase Current draw running FLA**** (A) for 208 V 3-phase Locked Rotor Amperage LRA (A) for Single compressor 230 V 1-phase Locked Rotor Amperage LRA (A) for Single compressor 400 V 3-phase Locked Rotor Amperage LRA (A) for Single compressor 208 V 3-phase
30
35
46
47
–
10
11
14
20
22
20
22
27
37
50
61
76
100
114
–
32
40
46
50
59
70
83
95
98
139
Min. chilled water flow (l /min.)
50
60
66
76
100
Min. seawater flow (l /min.)
38
46
56
64
80
Recommended seawater pump+
WB1500 WB2000
WB2500G WB3000G
WB2500G WB3000G
WB2500G WB3000G
WB3000G WB3500
Dimensions (L x W x H) (mm)
560 x 660 x 600
560 x 694 x 625
560 x 694 x 625
560 x 683 x 675
560 x 790 x 675
Dimensions (L x W x H) (inch)
22 x 26 x 23.6
22 x 27.3 x 24.6
22 x 27.3 x 24.6
22 x 26.9 x 26.6
22 x 31.1 x 26.6
Dimensions (L x W x H) (mm) tropical
560 x 660 x 625
560 x 694 x 625
560 x 694 x 625
560 x 683 x 675
560 x 790 x 725
Dimensions (L x W x H) (inch) tropical
22 x 26 x 24.6
22 x 27.3 x 24.6
22 x 27.3 x 24.6
22 x 26.9 x 26.6
22 x 31.1 x 28.5
Weight (kg)
90
95
100
130
160
Available options 230 V / 1-phase
–
c
c
c
c
208 V / 3-phase
c
c
c
c
c
Reverse Cycle Heating
g
g
g
g
g
Cool Only version
–
–
–
–
–
Tropicalized version
c
g
c
g
n
Soft Start 400 V / 230 V / 208 V
c / c / –
c / c / –
c / c / –
c / – / –
c / – / –
Upgrade box /MCA Box
c
c
c
c
c
Silent Block
c
c
c
c
c
General note: Values in this table given for 50 Hz only. 60 Hz data available on request. * BTU / h are based on 7 °C evaporating
g Standard
c Optional – Not available
The BlueCool P-Series: ■ Wide product range for medium and large size boats ■ Scroll compressors for heavy duty applications ■ Low starting surge through staged compressor starts ■ 208 V, 230 V and 400 V systems available ■ Many customization options with different electronics, tropical versions, vibration dampingand many other features ■ Fully independent refrigerant circuits in multiple compressor units provide high system availability ■ Power output continuously adapted to cooling demand ■ Very robust stainless steel design for heavy duty use
temperature and 38 °C condensing temperature.
** Amperage values for core unit at nominal conditions at 50 Hz. **** FLA (Full Load Amperage) is the current draw at maximum conditions. + Recommendation only. Pump size shall be adapted to application constraints in order to always ensure minimal sea water flow. ++ BlueCool P-Series systems are tested and approved by Webasto for 50 / 60 Hz operation.
99