Power required for remote OLT

For our sample 100,000 home system, we will look at 10 Cabinets of Centralised Remote PON, 400 Node PON units at 64 homes per PON, and 200 Node PON units at 128 homes per PON. This is what we can expect for annual electricity cost:

Electricity $/kWh Cabinet

Node PON 64 homes

Node PON 128 homes

$0.10 $0.15 $0.20 $0.25 $0.30 $0.10 $0.15 $0.20 $0.25 $0.30

$19,710 $29,565 $39,420 $49,275 $59,130

$65,700 $98,550 $131,400 $164,250 $197,100

$32,850 $49,275 $65,700 $82,125 $98,550

Cost per Home

$0.20 $0.30 $0.39 $0.49 $0.59

$0.66 $0.99 $1.31 $1.64 $1.97

$0.33 $0.49 $0.66 $0.82 $0.99

Battery maintenance

In the case of the cabinet or shelter-based PON, there are only up to 10 sites with which to be concerned. This is a small battery maintenance consideration. We will budget $20K/year for our sample system, or $0.20 per customer. For the Node PON with conventional four 64 home PONs per unit, or 250 homes per housing, we can estimate battery maintenance as follows:

NodePON Battery Repl. Years

4 years

64 Home PON

600 120

units

unit cost unit labor

$72,000 $300,000 $372,000

50

Total

Total per home

$3.72

And for higher split-ratio deployments leveraging four 128 home PONs per unit, or 500 homes per housing:

128 Home PON

300 120 500

units

unit cost unit labor

$36,000 $150,000 $186,000

Total

Total per home

$1.86

100

Volume 47 No.1 MARCH 2025