GARN® GN2000 | Emissions Report

Report No. G100463637MID-005R2 Report Revised Date: January 26, 2015

Page 6 of 15

Client: Dectra Corporation

Model: WHS2000

II. SUMMARY OF TEST RESULTS

II.A EPA Results

Table 1A. Data Summary Part A

W fuel

MC ave

Q in

Q out



Category

Load % Capacity

Target Load Btu/hr 30,000 40,000 75,000 200,000

Actual Load Btu/hr 30,000 40,000 75,000 200,000

Actual Load

Test Duration

Wood Weight as-fired

Wood Moisture

Heat Input

Heat Output

% of Max

hrs

lb

% DB 23.60 23.60 23.60 23.60

Btu

Btu

I

15% of Max 20% of Max 37.5% of Max Max Capacity

15% 20%

26.5 20.3 11.1

158.51 158.51 158.51 158.51

1,098,058 1,098,058 1,098,058 1,098,058

795,589 810,695 832,835 849,404

II

III IV

37.5% 100%

4.2

Table 1B. Data Summary Part B

 del-HHV 

 del-LHV

E

E

E g/hr

E g/kg

Delivered Efficiency LHV

Load % Capacity

Total PM Emissions

PM Output Based

PM Output Based

PM Factor

Delivered Efficiency HHV

Category

PM Rate

%

g

lb/mmBtu Out

g/MJ 0.031 0.030 0.030 0.029

g/hr 0.98 1.28 2.34 6.13

g/kg

%

I

15% of Max

26.0 26.0 26.0 26.0

0.072 0.071 0.069 0.067

0.447 0.447 0.447 0.447

72.03% 73.40% 75.41% 76.91%

77.6% 79.0% 81.2% 82.8%

II

16-24% of Max 25-50% of max Max capacity

III IV

Made with FlippingBook - professional solution for displaying marketing and sales documents online