Report No. G100463637MID-005R2 Report Revised Date: January 26, 2015
Page 8 of 15
Client: Dectra Corporation
Model: WHS2000
II.D Summary of Other Data
Run 1
Run 2
Run 3
Standby
Units
Steel Mass Water Mass
3574
3574
3574
3574 lbs 15588 lbs
15588
15588
15588
Fuel Load Weight Fuel MC (dry basis)
156.69
153.37
159.79
lbs
24.56
23.02
23.24
%
Kindling Mass
1.85
1.95
1.87
lbs
Kindling MC (dry basis)
10
10
10
%
Starting system temp. Ending System Temp. Average Room Temp.
120.28 172.20
125.64
124.70 180.50
172.20 F 169.20 F
179.6 79.06
75.94
78.53
77.21
Burn Time Burn Time
162 2.70
166 2.77
171 2.85
Minutes
Hours
Standby Test Duration
18 Hours
HHV
8600
8600
8600
BTU/lb
Dry Fuel Weight
58
57
60
Kg
Burn Rate
21.42
20.74
20.91
Kg/hr
Input
1,096,339
1,087,444
1,129,655 889,753 859,730
BTU BTU BTU
Heat Stored
828,952
860,486
Average
Standby Loss Rate Total Emissions Total Emissions
28.4 BTU/hr-F
25.291
20.147
32.674
Grams
0.056
0.044
0.072
lbs
Category I Output Rate Category II Output Rate Category III Output Rate Category IV Output Rate Output Time Cat I Output Time Cat II Output Time Cat III Output Time Cat IV Category I Efficiency Category II Efficiency Category III Efficiency Category IV Efficiency Category I Emissions Category II Emissions Category III Emissions Category IV Emissions
30000 40000 75000
30000 40000 75000
30000 40000 75000
2416 BTU/hr 2416 BTU/hr 2416 BTU/hr 2416 BTU/hr
200000
200000
200000
Average
25.6 19.5 10.7
26.5 20.3 11.1
27.4 21.0 11.5
26.5 Hours 20.3 Hours 11.1 Hours 4.2 Hours
4.1
4.3
4.2
Average
70.0% 71.3% 73.3% 74.7% 0.073 0.071 0.069 0.068
73.2% 74.6% 76.7% 78.2% 0.056 0.055 0.053 0.052
72.9% 74.3% 76.3% 77.8% 0.087 0.086 0.084 0.082
72.0% 73.4% 75.4% 76.9% 0.072 0.071 0.069 0.067
lb/mmBTU output
lb/mmBTU output
lb/mmBTU output
lb/mmBTU output
Made with FlippingBook - professional solution for displaying marketing and sales documents online