Henry Product Guide by Boise Cascade

® LF Liquid-Applied Flashing

Air-Bloc

or pigments.

Fill open joints, seams and cracks wi der than 1/8” (3 mm) up to ½” (13 mm) with 925 BES Sealant or Air-Bloc  LF prior to final application of Air-Bloc  LF .

Apply : Apply Air-Bloc  LF to substrate in a serpentine fashion using appropriate caulking gun and then spread using a trowel, joint knife or roller to achieve a monolithic membrane over the rough opening surfaces. Regularly monitor wet mil thickness during application to assure adequate coverage. Air-Bloc  LF can be applied in a single coat. Spread uncured Air-Bloc  LF to cover the inside of the rough opening and extend a minimum of 4” (100 mm) over the surface of the exterior wall. If a continuous air barrier such as Air-Bloc ® or Blueskin ® air barriers are used over the exterior wall, overlap Air- Bloc  LF a minimum o f 2” (50 mm) over adjacent membranes.

Coverage Rates : Apply per published architectural specifications. Typical application rates include: • Smooth Surfaces such as exterior gypsum sheathing or formed concrete: 10 ft 2 (0.9 m 2

) per 20 oz (0.6 L) sausage to give

a wet film thickness of 25 mils (0.6 mm)

Rough Surfaces such as CMU: 6 ft 2

2 ) per 20 oz (0.6 L) sausage to give a wet film thickness of 40 mils (1 mm)

(0.6 m

Coverage (Linear Feet)

Coverage (Linear Meters)

Wet Film Thickness (mils)

Wet Film Thickness (mils)

15

20

25

30

35

40

15

20

25

30

35

40

1

201

150

120

100

86

75

2.5

61.1 45.8 36.7 30.6 26.2 22.9

2

100

75

60

50

43

38

5

30.6 22.9 18.3 15.3 13.1 11.5

3

67

50

40

33

29

25

7.5

20.4 15.3 12.2 10.2

8.7

7.6

4

50

38

30

25

21

19

10

15.3 11.5

9.2

7.6

6.5

5.7

5

40

30

24

20

17

15

12.7 12.2

9.2

7.3

6.1

5.2

4.6

6

33

25

20

17

14

13

15

10.2

7.6

6.1

5.1

4.4

3.8

12

17

13

10

8

7

6

100

1.6

1.2

0.9

0.8

0.7

0.6

Per 20 oz. (0.6L) sausages

Per 20 oz. (0.6L) sausages

The above reference chart is based on theoretical coverage calculations for a smooth surface. Rough surfaces can reduce coverage rates significantly depending on texture and porosity of surface.

Limitations : Air-Bloc  LF can be exposed for up to 6 months but is not designed for permanent exposure to ultra-violet light and should be covered as soon as practical after application. Application at temperatures below 40  F (4  C) will slow curing. In low humidity conditions, curing may be aided by lightly misting Air-Bloc  LF with water.

Many silicone sealants show excellent adhesion to Air-Bloc  LF . Contact the sealant manufacturer for more information.

Packaging

20 oz (0.6 L) sausages

® Company , 999 N. Sepulveda Blvd., Ste. 800, El Segundo, CA 90245 Tel: 800-486-1278 Email: techservices@henry.com www.henry.com

Henry

Revision Date: 8/11/2016

Made with FlippingBook Digital Publishing Software