ECS MgO Corp. Internal & External Cladding Systems

Contents

BCA Codes

3

General

4

Fire Performances Thermal and Acoustic Insulation

Wall Installation

4

Timber Frame Separation Walls

5

Steel Frame Separation Walls

6

External Fire Rated Walls

7

Floor Installation

8

Ceiling Installation

9

Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

Extract of ResCom Testing to the BCA:

BCA Volume One 2013:

• BCA Volume Two 2013: Part 3.5.3.3, Fibre cement planks and weatherboard cladding. • BCA Volume Two 2013: Part 3.5.3.4, Fibre cement sheet wall cladding. • BCA Volume Two 2013: Part 3.5.3.5, Eaves and soffit linings. • BCA Volume Two 2013: Part 3.7.1, Fire separation for FRL to (load bearing timber frame 60/60/60, load bearing metal frame 90/90/90, non-load bearing FRL -/120/120) – including SA state variation. • BCA Volume Two 2013: Part 3.7.4, Bushfire areas including all state variations to Part 3.7.4.0 and 3.7.4.1, as tested under AS1530 Part 8.1 - 2007 and AS1530 Part 8.2 - 2007 – including NSW state variation, SA state variation. TAS state variation.

Part C1.8 Light Weight Construction,

• C1.10 Fire Hazard including NSW State Variation,

C1.12 Non-Combustible materials Load bearing Timber Frame 60/60/60 utilising 10mm ResCom (R) Load bearing Metal Frame 90/90/90 utilising 10mm ResCom (R) Non-load bearing walls FRL (Single board performance) 5mm -/20/20 10mm -/60/60 10mm -/90/90

12mm -/120/120 14mm - /180/180 15mm -/240/240 18mm Structural Flooring 120/120/120

BCA Volume Two 2013: Part 3.8.6, Sound insulation to RW 64+ctr

• BCA Volume One 2013: Part F5 Sound Insulation to Rw 60+ctr

Made with FlippingBook - professional solution for displaying marketing and sales documents online