3.3 Shipper and MIPL(C)L agree to deliver and receive Gas at hourly rates of flow as nearly constant as possible. Departures from scheduled daily deliveries due to the inability of Shipper or MIPL(C)L to maintain precise control shall be kept to a minimum permitted by operating conditions. Notwithstanding the foregoing, the maximum hourly rate of flow at the Point of Receipt shall not be greater than one hundred and twenty percent (120%) of the hourly equivalent of the Contract Demand at the Point of Receipt and at the Point of Delivery.
3.4 Shipper agrees to ensure that at all times that Gas is delivered hereunder, that an Energy Balance will exist between the following:
(a) the Energy received by MIPL(C)L at Point of Receipt, less any Unnacounted For Gas and Fuel Gas, if applicable; and
(b)
the Energy delivered by MIPL(C)L at the Point of Delivery.
Amounts of Gas delivered, and approved by Gas Control, for the purposes of Energy Balancing or making up Impaired Receipts or Deliveries are not included in determining the Energy Balance. 3.5 In the event that Customer on any Day or number of Days desires to deliver an amount of Gas at a Point of Receipt which is in excess of the Contract Demand, other than those amounts delivered for the purposes of Energy Balances or making up Impaired Receipts and Deliveries, Customer shall make application in writing to MIPL(C)L for an Authorized Overrun Capacity. 3.6 In the event a Daily Energy Imbalance exists at any time, MIPL(C)L may take any action whatsoever to correct the Daily Energy Imbalance, including, without limitation, restricting the flow of Gas at either the Point of Receipt or the Point of Delivery; provided however, that MIPL(C)L agrees not to take any such action if the Daily Energy Imbalance has been corrected.
ARTICLE IV - QUALITY OF GAS
4.1 The Gas delivered at the Point of Receipt hereunder shall at all times comply with the following quality requirements:
(a) Heating Value: The Gas delivered hereunder shall have a Heating Value not greater than thirty-nine and no hundredths (39.00) MJ's per Cubic Meter nor less than thirty-six and no hundredths (36.00) MJ's per Cubic Meter. However, on a non-precedent setting basis, and at the option of MIPL(C)L,