Many Islands Pipe Lines (Canada) Limited MIPL(C)L
General Terms and Conditions
and three hundred and twenty-five thousandths (101.325) kilopascals absolute and a temperature of fifteen degrees (15 o ) Celsius.
(x)
Shall not exceed a temperature of fifty degrees (50 o ) Celsius at the Point of Receipt hereunder.
4.2 MIPL(C)L, at its expense, may make tests of the Gas being delivered hereunder to determine whether the Gas complies with the quality requirements as set forth in Paragraph 4.1. MIPL(C)L shall have the right, by notice, to require Shipper to remedy any deficiency, within the time specified by MIPL(C)L, in the quality of the Gas and, in the event such deficiency is not remedied, the right to require Shipper to discontinue deliveries hereunder until such deficiency is remedied. During the period of such discontinuance, Shipper shall continue to pay any Demand Charges under the applicable toll. 4.3 The provisions of these General Terms and Conditions with regard to this Article IV and the specifications contained in Paragraph 4.1 shall apply, mutatis mutandis, to Gas that is delivered hereunder at the Point of Receipt in a common stream with Gas of other Shippers ("Common Stream Gas") and to the extent that the Common Stream Gas meets the specifications of this Paragraph 4.1, then Shipper shall be deemed to have complied with its obligations under this Article IV and to the extent that the Common Stream Gas fails to meet such specifications, Shipper shall be deemed to have failed to comply with the obligations under this Article IV. 4.4 All Gas delivered by MIPL(C)L to Shipper at the Point of Delivery shall have the Heating Value and quality that results from the Gas having been commingled in the Gas Transmission System. 4.5 Notwithstanding the provisions of Paragraphs 4.1, 4.2, 4.3 and 4.4, if the Gas quality specifications required at the Point of Delivery differ from those set forth in Paragraphs 4.1, 4.2 and 4.3 of this Article IV, then MIPL(C)L reserves the right to require Shipper to deliver Gas with Gas quality specification identical to those required at the Point of Delivery.
ARTICLE V - MEASUREMENT OF GAS
The measurements and tests of the Gas delivered hereunder shall be governed by the following:
5.1 All measuring and testing equipment, devices and materials required herein shall be of standard manufacture and type, and with all related equipment, appliances and buildings shall be installed, maintained and operated, or furnished by MIPL(C)L at
Page 6
June 1, 2016