Many Islands Pipe Lines (Canada) Limited MIPL(C)L
General Terms and Conditions
5.4 MIPL(C)L and Shipper shall have the right to inspect equipment installed or furnished by the other, and the charts and other measurement or testing data of the other at all times during business hours; but the reading, calibration and adjustment of such equipment and changing of charts shall be done only by the party installing and furnishing the same. Unless the parties otherwise agree each party shall preserve all original test data, charts and other similar records in such party's possession for a period of at least six (6) years. 5.5 In the case where the Gas hereunder is commingled with other Gas prior to delivery at the Point of Receipt, Shipper will be responsible for all common stream arrangements. Shipper shall provide such assurances and other information as MIPL(C)L may reasonably require to confirm that Shipper has made such arrangements, indicating the party which is to provide an accounting of the Gas in common stream. Service under these General Terms and Conditions is contingent on Shipper's compliance with the provisions of this Paragraph prior to the Date of Initial Delivery hereunder.
ARTICLE VI - STANDARDS OF MEASUREMENT AND TESTS
The standards of measurement and tests for the Gas delivered hereunder shall be governed by the following:
6.1 The unit of volume for purposes of measurement shall be one (1) Cubic Meter and will be converted to energy using the Actual Heating Value.
6.2
Amounts of Gas for billing purposes shall be determined to the nearest GJ.
6.3 All instruments and apparatus used for determining volume, pressure, temperature, relative density and total Heating Value shall be of a type approved for their intended use under the provisions of the Electricity and Gas Inspection Act being Statutes of Canada A80-81-82-83, Chapter 87, or as amended, where such approvals are required. All measurements, calculations and procedures used in determining the volume hereunder, except for the correction for deviation from Boyle's Law, shall be made in accordance with the Electricity and Gas Inspection Act (Supra) and all applicable regulations issued pursuant thereto. The correction for the deviation from Boyle's Law shall be determined from data contained in "PAR Research Project NX- 19" as published by the American Gas Association in 1962, or any subsequent revisions thereof acceptable to MIPL(C)L and Shipper.
6.4 Except as hereinbefore set forth, in the event of any conflict between these General Terms and Conditions and the Electricity and Gas Inspection Act (Supra), related to