Many Islands Pipe Lines (Canada) Limited Tariff

Many Islands Pipe Lines (Canada) Limited MIPL(C)L

General Terms and Conditions

(a) by the use of a standard recording calorimeter installed, operated and maintained by MIPL(C)L, in which case the Heating Value of the Gas delivered each Month shall be determined by weighting volumetrically the daily Heating Value, or (b) by tests of samples of such Gas conducted by MIPL(C)L. The Gas samples to be tested may be either spot samples or continuous samples but shall be taken in such a manner and at such times to ensure that the samples taken and tested are representative of the Gas delivered hereunder. Samples shall be concurrent with measurement of the Gas delivered or if only one such test is made during a particular Month, the Heating Value established by such test shall have effect upon the first Day of the Month next succeeding the Month in which such test was made or if more than one such test was made during a particular Month, the results of such tests shall be averaged to the nearest one-one hundredth (.01) MJ per Cubic Metre and the resulting figure shall likewise have effect upon the first Day of the Month next succeeding the Month in which such tests were made; PROVIDED that the Heating Value established by the test or tests made during the first Month shall also have effect during the first Month. Upon a figure having effect, the same shall remain in force and effect until the Effective Date of the next succeeding figure, and each figure, during the period in which it has effect, shall be deemed to be the Heating Value of all Gas delivered during such period. 6.9 If there are any compression facilities upstream from the Point of Receipt, Shipper shall cause to be provided sufficient pulsation dampening equipment to ensure that the compression facilities do not interfere with the operation of MIPL(C)L's facilities.

6.10 MIPL(C)L, at it sole discretion, may use the measurement or testing equipment of an upstream or downstream pipeline, providing it meets industry standards.

(a) MIPL(C)L and Shipper hereby agree that in the absence of manifest error and notwithstanding anything contained elsewhere in these General Terms and Conditions, if the Point of Delivery is a TCPL interconnection, TCPL's, not MIPL(C)L's or TransGas', measuring and testing equipment shall be used to determine the quantity and Heating Value of Gas delivered at the Point of Delivery under these General Terms and Conditions and TCPL's measuring and testing of Gas procedures shall apply. (b) Shipper acknowledges that MIPL(C)L shall have the option to install check measuring equipment at the Point of Delivery which shall be used to determine quantity and quality only where the TCPL equipment is found to be malfunctioning.

Page 11

June 1, 2016

Made with FlippingBook Ebook Creator