RTT Powder Booths Installation Manual

#1 High Volume

Compressed Air Inlet

#2

Some of the compressed air bleeds out of the pilot port to the solenoid enclosure

Compressed air feeds from the pilot port on each pulse valve to the solenoid enclosure.

#3

Compressed air is vented out of this port only when the solenoid is open.

#4

The pulse valve acts like a high volume switch for compressed air. Compressed air is fed into the inlet of the valve and some of the air bleeds off th r ough the pilot port on the top where it feeds over to the solenoid enclosure. The solenoid enclosure is where the air stops, which is what keeps the pulse valve closed. As long as air is not allowed to continuously bleed out of the pilot port on top, then the pulse valve will remain closed. When air is allowed to bleed out of the pilot port on top, then the pulse valve will open until the pilot port is blocked off and p r essure is allowed to rebuild.

27