RTT Powder Booths Installation Manual

5.Gen er al Lighting Fixture 5.1 Light Fixtures

Prevent serious injury or death. Electrical installations must be performed by qualified electricians. Installation must conform to all national, local, and provincial codes and standards. WARNING

1. Place light fixture into booth panel, center in opening, and mark locations for mounting holes. 2. Install light fixture in panel from outside of booth as shown in drawing. 3. Caulk perimeter of light fixture lens frame with appropriate caulking. 4. The fixture is provided with an interlock switch that has a normally open contact, which opens when the fixture lens is removed from fixture. The switch is to be wired to disable spray equipment used in spray booth.

FIXTURE ENCLOSURE

LENS, FRAME GLASS, AND GASKET

LENS, FRAME FASTENER

FIXTURE FASTENER

CAULK SEAM

BOOTH WALL PANEL

MOUNTING DETAIL

5/16” UNC 18 HEX FLANGE NUT

CAUTION: WHEN TIGHTENING LENS FRAME FASTENERS, TIGHTEN USING HAND TOOLS ONLY. TIGHTEN UNTIL SIDES OF METAL LENS FRAME MAKES CONTACT WITH FIXTURE ENCLOSURE. OVER TIGHTENING WILL CAUSE LENS FRAME TO WARP AND WILL BREAK DOWN VAPOR SEAL OF LENS

PAINT SPRAY BOOTH WALL PANEL

5/16” UNC 18 HEX HEAD NUT