Cables for Motion

Application parameters Application parameters* CONTROL 200/200 C

CONTROL 400/400 C

POWER 400/400 C

CONTROL / POWER 700/700 C

SYSTEM S 700 SYSTEM M 700

subject to cable type subject to cable type subject to cable type

Acceleration a

up to 10 m/s 2 up to 3,5 m/s

up to 20 m/s 2

up to 20 m/s 2

up to 50 m/s 2 up to 20 m/s

Speed v, self-supporting

up to 5 m/s up to 5 m/s

up to 5 m/s up to 3 m/s

Speed v, gliding

up to 2 m/s

up to 5 m/s

Travel length recommended application areas

up to 25 m up to 50 m up to 50 m up to 500 m up to 50 m

subject to cable type

subject to cable type

subject to cable type

subject to cable type

subject to cable type

DESINA

Cold-resistant

• • •

• •

Minimum bend radius, unshielded Minimum bend radius, shielded

KR min ≥ 10 x Ø KR min ≥ 10 x Ø

KR min ≥ 7,5 x Ø KR min ≥ 7,5 x Ø

KR min ≥ 7,5 x Ø KR min ≥ 7,5 x Ø

KR min ≥ 7,5 x Ø KR min ≥ 7,5 x Ø*

subject to cable type

UL- Approval Combined UL/CSA- Approval

+

+

+

+

+

subject to cable type

subject to cable type

subject to cable type

+

+

subject to cable type

Operating temperature range

- 5 to + 80 °C

- 5 to + 80 °C

- 5 to + 80 °C

- 30 to + 90 °C*

UV-resistance

+

+

+

• jacket coloured ••• jacket black

• jacket coloured ••• jacket black

OEM- specification OEM- specification

+

+

CFC-free

+ +

+ +

+ +

+ + +

+ +

flame-retardant

subject to cable type

halogen-free

oil-resistant silicone-free

+ +

+ +

+ +

+ +

+ +

+ Yes –No • suitable •• well suitable ••• very well suitable * Recommended values for the design of KABELSCHLEPP cable carrier systems, deviations possible in case of data cables.

69