U-value calculations according to EN ISO 10077-2 and ISO 15099
1230
U-value fixed element
Hansen Millennium ™ with:
Glazing: Double glazed thermal Ug=1.0 W/m²K which provides the construction with a total U-value of Uw=1.3 W/m²K Glazing: Triple glazed thermal window Ug=0.5 W/m²K which provides the construction with a total U-value of Uw=0.8 W/m²K
•
low U-values
• slim profiles and optimal light transmittance • efficient thermal break • warm edge and optimal glass construction
12
We reserve the right to make alterations and modifications.