YUKON
SMHM-160P(/3) -3/9
Temperatuur waterstroom (°C)
35
40
45
50
55
60
65
Pcal
Pcal
Pcal
Pcal
Pcal
Pcal
Pcal
Pabs COP
Pabs COP
Pabs COP
Pabs COP
Pabs COP
Pabs COP
Pabs COP
8.83
8.64
8.45
8.26
8.18
-
-
-25
5.08 1.74
5.53 1.56
5.70 1.48
6.01 1.38
6.30 1.30
-
-
-
-
-20 10.56
10.39
10.59
9.99
9.82
9.37
8.66
5.39 1.96
5.68 1.83
5.94 1.78
6.14 1.63
6.28 1.56
6.45 1.45
6.21 1.39
-15 11.96
11.78
11.60
11.60
11.19
10.45
9.67
5.28 2.27
5.74 2.05
6.11 1.90
6.56 1.77
6.26 1.79
6.24 1.67
6.36 1.52
-10 12.55
12.31
12.08
11.70
11.30
10.85
10.37
5.39 2.33
5.92 2.08
5.92 2.04
6.15 1.90
5.95 1.90
6.20 1.75
6.02 1.72
13.18
12.95
12.50
12.23
12.40
11.65
10.85
-7
5.31 2.48
5.61 2.31
5.56 2.25
5.96 2.05
6.05 2.05
6.32 1.84
6.05 1.79
13.38
13.14
12.89
12.28
11.85
11.39
10.83
-5
5.10 2.62
5.46 2.40
5.72 2.25
5.83 2.11
5.68 2.09
6.10 1.87
5.98 1.81
14.05
13.83
13.57
13.28
12.91
11.91
11.29
0
4.64 3.03
4.93 2.81
5.24 2.59
5.58 2.38
5.70 2.26
5.83 2.04
5.83 1.94
15.77
15.49
15.19
14.87
14.74
14.19
13.21
5
4.24 3.72
4.53 3.42
4.83 3.15
5.14 2.89
5.54 2.66
5.70 2.49
5.60 2.36
17.57
17.21
16.85
16.42
16.00
15.59
14.71
7
4.25 4.13
4.55 3.78
4.85 3.47
5.17 3.18
5.70 2.81
5.93 2.63
6.06 2.43
18.31
17.92
17.50
17.06
16.89
16.34
15.00
10
4.00 4.58
4.29 4.18
4.60 3.81
4.92 3.47
5.38 3.14
5.79 2.82
5.75 2.61
Prestaties gemeten in overeenstemming met norm EN14511 Pcal: Afgegeven verwarmingsvermogen (kW) Pabs: Geabsorbeerd elektrisch vermogen (kW) * Vermogen gemeten bij maximale compressorfrequentie * Gemeten vermogen met geïntegreerde ontdooicyclus * Elektrisch vermogen gemeten exclusief circulatiepomp * Omgevingstemperatuur buiten °C droge bol