Sinclair B2B Catalogus

YUKON

SMHM-160P(/3) -3/9

Temperatuur waterstroom (°C)

35

40

45

50

55

60

65

Pcal

Pcal

Pcal

Pcal

Pcal

Pcal

Pcal

Pabs COP

Pabs COP

Pabs COP

Pabs COP

Pabs COP

Pabs COP

Pabs COP

8.83

8.64

8.45

8.26

8.18

-

-

-25

5.08 1.74

5.53 1.56

5.70 1.48

6.01 1.38

6.30 1.30

-

-

-

-

-20 10.56

10.39

10.59

9.99

9.82

9.37

8.66

5.39 1.96

5.68 1.83

5.94 1.78

6.14 1.63

6.28 1.56

6.45 1.45

6.21 1.39

-15 11.96

11.78

11.60

11.60

11.19

10.45

9.67

5.28 2.27

5.74 2.05

6.11 1.90

6.56 1.77

6.26 1.79

6.24 1.67

6.36 1.52

-10 12.55

12.31

12.08

11.70

11.30

10.85

10.37

5.39 2.33

5.92 2.08

5.92 2.04

6.15 1.90

5.95 1.90

6.20 1.75

6.02 1.72

13.18

12.95

12.50

12.23

12.40

11.65

10.85

-7

5.31 2.48

5.61 2.31

5.56 2.25

5.96 2.05

6.05 2.05

6.32 1.84

6.05 1.79

13.38

13.14

12.89

12.28

11.85

11.39

10.83

-5

5.10 2.62

5.46 2.40

5.72 2.25

5.83 2.11

5.68 2.09

6.10 1.87

5.98 1.81

14.05

13.83

13.57

13.28

12.91

11.91

11.29

0

4.64 3.03

4.93 2.81

5.24 2.59

5.58 2.38

5.70 2.26

5.83 2.04

5.83 1.94

15.77

15.49

15.19

14.87

14.74

14.19

13.21

5

4.24 3.72

4.53 3.42

4.83 3.15

5.14 2.89

5.54 2.66

5.70 2.49

5.60 2.36

17.57

17.21

16.85

16.42

16.00

15.59

14.71

7

4.25 4.13

4.55 3.78

4.85 3.47

5.17 3.18

5.70 2.81

5.93 2.63

6.06 2.43

18.31

17.92

17.50

17.06

16.89

16.34

15.00

10

4.00 4.58

4.29 4.18

4.60 3.81

4.92 3.47

5.38 3.14

5.79 2.82

5.75 2.61

Prestaties gemeten in overeenstemming met norm EN14511 Pcal: Afgegeven verwarmingsvermogen (kW) Pabs: Geabsorbeerd elektrisch vermogen (kW) * Vermogen gemeten bij maximale compressorfrequentie * Gemeten vermogen met geïntegreerde ontdooicyclus * Elektrisch vermogen gemeten exclusief circulatiepomp * Omgevingstemperatuur buiten °C droge bol

Technische gegevens onder voorbehoud van wijzigingen door de fabrikant

130

Made with FlippingBook flipbook maker