Sinclair B2B Catalogus

CAPACITEITSTABELLEN KOELING

YUKON

SMHM-100P / SMHM-100P/3

Temperatuur waterstroom (°C)

5

10

15

20

25

Pref

Pref

Pref

Pref

Pref

Pabs

EER

Pabs

EER

Pabs

EER

Pabs

EER

Pabs

EER

-

-

8.12

9.40

11.00

-5

-

-

-

-

0.67

12.09

0.71

13.16

0.82

13.48

-

-

8.05

9.32

10.67

0

-

-

-

-

0.76

10.55

0.77

12.11

0.83

12.80

-

-

7.82

9.05

10.40

5

-

-

-

-

0.81

9.60

0.82

11.07

0.86

12.16

-

-

7.65

8.88

10.24

10

-

-

-

-

0.86

8.84

0.86

10.28

0.88

11.65

7.23

8.49

9.91

11.52

12.17

15

1.45

4.97

1.46

5.83

1.62

6.10

1.59

7.25

1.43

8.52

7.81

9.15

10.66

12.23

12.49

20

1.91

4.09

1.96

4.68

1.99

5.35

1.99

6.15

1.63

7.65

8.20

9.58

11.11

12.80

13.00

25

2.40

3.41

2.49

3.84

2.58

4.31

2.52

5.08

1.98

6.55

8.23

9.60

11.16

12.81

13.63

30

2.86

2.88

2.98

3.22

3.12

3.58

3.16

4.05

2.66

5.13

6.76

7.95

9.25

10.68

11.99

35

2.44

2.77

2.54

3.13

2.65

3.49

2.75

3.89

2.75

4.36

6.18

7.26

8.49

9.89

11.27

40

2.35

2.63

2.45

2.96

2.55

3.33

2.62

3.78

2.73

4.13

5,20

6,11

7,33

8,53

10,68

43

3,72

1,40

3,26

1,87

3,02

2,43

3,19

2,67

3,26

3,27

YUKON

SMHM-120P -3(/9)

Temperatuur waterstroom (°C)

5

10

15

20

25

Pref

Pref

Pref

Pref

Pref

Pabs

EER

Pabs

EER

Pabs

EER

Pabs

EER

Pabs

EER

-

-

9.88

11.40

12.45

-5

-

-

-

-

0.76

12.96

0.82

13.93

0.85

14.64

-

-

10.00

11.54

12.60

0

-

-

-

-

0.82

12.18

0.84

13.67

0.88

14.34

-

-

10.27

11.87

12.97

5

-

-

-

-

0.94

10.97

0.91

13.06

0.95

13.66

-

-

10.10

11.72

12.83

10

-

-

-

-

1.05

9.60

0.99

11.80

1.01

12.65

9.82

11.49

13.35

15.41

16.78

15

1.99

4.94

2.00

5.74

2.00

6.68

2.07

7.46

1.86

9.02

10.63

12.40

14.35

16.57

17.93

20

2.68

3.97

2.75

4.51

2.81

5.11

2.85

5.81

2.75

6.51

11.13

12.97

15.04

17.49

18.60

25

3.39

3.28

3.51

3.70

3.62

4.16

3.61

4.84

3.64

5.11

11.25

13.05

14.86

17.29

18.53

30

4.03

2.79

4.21

3.10

4.24

3.50

4.54

3.81

4.48

4.14

9.88

11.55

13.31

15.25

16.49

35

3.86

2.56

4.12

2.80

4.17

3.19

4.33

3.52

4.26

3.87

8.60

10.04

11.58

13.31

14.39

40

3.51

2.45

3.66

2.74

3.80

3.05

3.94

3.38

3.86

3.73

5,20

6,11

7,33

8,53

10,70

43

3,72

1,40

3,26

1,87

3,02

2,43

3,19

2,67

3,26

3,27

YUKON

SMHM-140P(/3) -3/9

Temperatuur waterstroom (°C)

5

10

15

20

25

Pref

Pref

Pref

Pref

Pref

Pabs

EER

Pabs

EER

Pabs

EER

Pabs

EER

Pabs

EER

-

-

10.12

11.58

12.73

-5

-

-

-

-

0.79

12.81

0.84

13.82

0.88

14.42

-

-

10.25

11.83

12.90

0

-

-

-

-

0.85

12.02

0.88

13.45

0.92

14.01

-

-

10.54

12.19

13.30

5

-

-

-

-

0.97

10.90

0.96

12.65

0.99

13.42

-

-

10.63

12.33

13.55

10

-

-

-

-

1.13

9.39

1.05

11.74

1.11

12.24

10.32

12.07

14.02

16.17

17.57

15

2.16

4.77

2.18

5.53

2.19

6.39

2.30

7.03

2.06

8.52

11.21

13.07

15.09

17.38

18.78

20

2.96

3.79

3.04

4.30

3.12

4.84

3.19

5.45

3.09

6.08

11.92

13.86

16.05

18.42

19.74

25

3.83

3.11

3.98

3.48

4.12

3.89

4.08

4.52

4.20

4.70

11.98

13.87

16.03

18.33

19.55

30

4.52

2.65

4.74

2.92

4.95

3.24

5.15

3.56

5.12

3.82

9.88

11.55

13.31

15.25

16.49

35

3.86

2.56

4.12

2.80

4.17

3.19

4.33

3.52

4.26

3.87

132

8.60

10.04

11.58

13.31

14.39

40

3.51

2.45

3.66

2.74

3.80

3.05

3.94

3.38

3.86

3.73

5,98

7,33

9,01

10,50

12,00

43

4,50

1,33

4,12

1,78

3,91

2,31

4,13

2,54

3,85

3,11

Prestaties gemeten in overeenstemming met norm EN14511 Pref: Koelcapaciteit (kW) Pabs: Geabsorbeerd elektrisch vermogen (kW) * Vermogen gemeten bij maximale compressorfrequentie * Elektrisch vermogen gemeten exclusief circulatiepomp * Omgevingstemperatuur buiten °C droge bol

Technische gegevens onder voorbehoud van wijzigingen door de fabrikant

Made with FlippingBook flipbook maker