2025 SiteOne Catalog - Eastern Canada

SiteOne ® Landscape Supply : LANDSCAPE LIGHTING.

EX TRANSFORMER

FX LUMINAIRE

150 watts Single 15-volt output tap Compatible with most plug-in astronomical timers and photocells Pool & Spa Rated! 6' Power Cord

Description

INSTALL AND MAINTAIN TRANSFORMER TO MEET APPLICABLE CODES

Part #: • Mount the rain-tight transformer at least one foot above ground level with the wire terminals facing down. NOTE: Do not energize transformer until installation of system is complete. • According to the requirements of the National Electric Code (NEC), direct burial rated wire is to be buried a minimum of 6” [152mm] beneath the surface of the ground. Description: EX150SS EX150M NOTE: If more cable is needed, contact your local Kichler ® Landscape distributor. 12GA cable can be purchased in lengths of 100'/30M (15501BK), 250'/76M (15502BK), 500'/152 (15505BK), and 1000'/304M (15506BK). 10 GA cable in lengths of 250'/76m (15504BK); 8 GA cable in lengths of 250'/76M (15503-BK). • Finding Transformer Load: Low voltage systems require the use of a transformer to reduce standard 120-VOLT power from your home to 12-VOLTS. To determine the transformer size you will need, add up the wattages of all lamps you plan to use. Select a transformer that matches as closely as possible to the total lamp wattage. For example, if you have 11 fixtures all rated at 24.4 watts, you will need a 300 watt (VA) transformer (11 x 24.4 = 268.4 watts). Generally, the total lamp load should not be less than one-third the transformers wattage rating, nor exceed its maximum wattage capacity. If your total wattage is too high, either divide the load between two transformers, or use a more powerful transformer. 150W Matte

use with landscape lighting systems only. ormer.

List Price: $368.99

as a component of a landscape lighting system where the suitability of e determined by CSA or local authorities having jurisdiction. To comply with xture should be installed by a qualified electrician. Au Canada. Pour être 15 CSA. Ce luminaire doit être installé par un électricien qualifié. more power supplies in parallel. overed by Article 680 Part E of the National Electrical Code, NFPA 70. y with provided conduit adapter plate. requires that wiring where concealed or extended through a building wall nduit. mounted close to power supply. Extension cords should not be used with hall be connected to a 115/120 volt covered GFCI receptacle marked “Wet

150W Stainless

$538.83

INSTALE Y MANTENGA DEL TRANSFORMADOR CUMPLIENDO LOS CÓDIGOS APLICABLES

LUXOR • Monte el transformador estanco a la lluvia por lo menos a un (1) pie arriba del nivel del terreno con los cables terminales mirando hacia abajo. NOTA: No energice el transformador hasta que se termine la instalación del sistema. • De acuerdo con los requisitos del Código Eléctrico Nacional (NEC por sus siglas en inglés), el alambre clasificado para soterrado directo se debe enterrar un mínimo de 6 pulgadas [152 mm.] debajo de la superficie del terreno. NOTA: Si se necesita más cable, comuníquese con el distribuidor local de Kichler ® Landscape. El cable calibre 12 GA se puede comprar en longitudes de 100 pies / 30 metros (15501BK), 250 pies / 76 metros (15502BK), 500 pies / 152 metros (15505BK) y 1000 pies / 304 metros (15506BK); el cable calibre 10 GA se puede comprar en longitudes de 250 pies / 76 metros (15504BK), y el cable calibre 8 GA en longitudes de 250 pies / 76 metros (15503BK). Description Part #: • Encontrar la carga del transformador: Los sistemas de baja tensión necesitan que se use un transformador para reducir a 12 VOLTIOS la corriente de 120 VOLTIOS estándar de su casa. Para determinar el tamaño del transformador usted necesita sumar el vataje de todas las lámparas que piensa utilizar. Escoja un transformador que corresponda tan cerca como sea posible al vataje total de las lámparas. Por ejemplo: Si usted tiene 11 artefactos, todos de 24.4 vatios, usted necesita un transformador de 300 vatios (VA) (11 x 24.4 = 268.4 vatios). Generalmente, la carga total de lámpara no debe ser menor de un tercio del régimen nominal de vataje de los transformadores, ni debe exceder la máxima capacidad de vataje. Si su vataje total es demasiado alto, o divida la carga entre dos transformadores o use un transformador más potente.

FX LUMINAIRE tado como un componente del sistema de alumbrado panorámico donde ombinación se determinará por CSA o las autoridades locales que a cumplir con los requisitos de CSA, este artefacto se debe instalar por . alimentaciones eléctricas en paralelo. biertas por el Artículo 680, Parte E del Código Eléctrico Nacional, NFPA 70. erior al aire libre. olamente con una placa adaptadora de conducto. onal exige que el cableado, donde esté escondido o extendido a través de debe estar encerrado en un conducto. e montar cerca de la alimentación eléctrica. al aire libre se debe conectar a un receptáculo de interruptor accionado a tierra, cubierto, de 115/120 voltios, marcado “lugar húmedo”, mientras ica se usa con el sistema de alumbrado panorámico solamente. ador.

300W Lighting control with zoning, dimming, and RGBW color creation capabilities, plus optional Wi-Fi control using Luxor® technology.

Description:

List Price: $3140.11 $1961.83

LUX300M LSAT300M Accessories WIFIMOD2

300W Controller, Matte Grey

300W Satellite, LUX300M Required

$540.04 $598.96

Wi-Fi Module, Controller Mount Wi-Fi Module Remote Mount Luxor Wireless Linking Module Add's Z & D to any fixture, 60W

WIFIMOD2RMT INSTALACIÓN DEL TRANSFORMADOR 1) Determine el lugar deseado donde montar el transformador. NOTA: Al decidir el lugar del montaje, se debe dar consideración a los requisitos indicados arriba. LCMLV 2) Monte el transformador en el lugar deseado, utilizando el herraje apropiado (no se incluye). 3) Parta el cable de calibre 16 aproximadamente 3” y pele 1/2” del aislamiento de cada alambre. 4) Inserte uno de los alambres pelados en uno de los agujeros del bloque de terminales y apriete el tornillo correspondiente. Repita para el alambre pelado restante. 5) Enchufe el cordón de la alimentación eléctrica en un tomacorriente estándar de 115/120 voltios. NOTA: El cordón de alimentación eléctrica se debe enchufar en un tomacorriente para exterior equipado con un interruptor accionado por corriente de pérdida a tierra. LINKMOD Description FUNCIONES DEL TRANSFORMADOR FOTO SENSOR: La bombilla se encenderá automáticamente cuando el área circundante se vuelva oscura. El sensor está equipado con un retardo de 30 segundos para evitar cualquier error de respuesta. La bombilla se apagará automáticamente si se detecta luz intensa durante más de 30 segundos. AJUSTES DEL TEMPORIZADOR: (FIG. 1) APAGADO SIN POTENCIA ENCENDIDO ENCENDIDO CONTINUO AUTOMÁTICO LA BOMBILLA SE ENCIENDE Y SE APAGA CON UN FOTO SENSOR 4H, 6H, 8H LA BOMBILLA SE ENCIENDE CON EL FOTO SENSOR Y SE APAGA 4, 6 U 8 HORAS MÁS TARDE. Part #: 10500610 10500715 10500720 INTERRUPTOR AUTOMÁTICO DE CIRCUITO: (LADO SECUNDARIO – LADO DE 12 VOLTIOS) • El interruptor automático de circuito disparará si hay un corto circuito o si el vataje total instalado excede el vataje de régimen nominal por circuito.0 • Para reposicionar el interruptor, empuje adentro el botón. • Si la unidad cicla encendiendo y apagando sin tener en cuenta el ajuste del temporizador, la unidad debe verificar una persona de servicio calificada. PROTECCIÓN TÉRMICA (LADO PRIMARIO – LADO DE 120 VOLTIOS) • Esta unidad está equipada con un protector térmico y apagará si se recalienta. INTERRUPTOR ALTO-BAJO Accessories 10500706 Para la emisión luminosa óptima, la tensión en el tomacorriente debe ser de 10 a 12 voltios. BAJO: Use si el vataje total es menos de la mitad del vataje del transformador, las distancias del cable son cortas, o si la tensión de arranque que viene de la casa es alta. ALTO: Use si el vataje transformador está total mente cargado (máxima capacidad de vataje), las distancias del cable son largas, o si la tensión de arranque que viene de la casa es baja.

in-lite TRANSFORMER INSTALLATION ion for mounting transformer. NOTE: When deciding location of mounting taken for the requirements listed under “Install and Maintain sired location using the appropriate hardware (not included). imately 3”, and strip 1/2” insulation off each wire. res into one of the holes on terminal block and tighten the corresponding ning bare wire. into standard 115/120 volt receptacle. NOTE: The power supply cord must er tight receptacle equipped with a Ground Fault Interrupter (GFCI). TRANSFORMER FUNCTIONS ill light automatically when surroundings turn dark. Sensor is equipped avoid any error in response. Bulb will turn off automatically if intense light is econds. 1) S ON S ON AND OFF WITH PHOTO SENSOR S ON WITH PHOTO SENSOR, TURNS OFF 4, 6 OR 8 HOURS LATER. VOLT SIDE) here is a short or if total wattage installed exceeds rated wattage per utton in. off without regard to the timer setting, it should be checked by a qualified

$297.52

SMART HUB

3 ZONE

App Control, 3 Zone, Bluetooth Low Energy

Description:

List Price: $666.40

150VA, Smart Hub

$168.64 $61.20 $175.44

Smart Move - Motion Detector

Smart Hub Protector (Outdoor Install)

Smart Extender

LT SIDE) h a thermal protector and will shut off if overheated.

KICHLER HI-LOW SWITCH e voltage at socket should be between 10 and 12 volts. ge is less than half of the transformer capacity, cable distances are short voltage coming from the house is high. rmer is fully loaded (maximum wattage capacity), cable distances are long voltage is low coming from the house.

ECONOMY SERIES

Integrated timer and photocell On/Off, Photocell and 4/6/8 Hour Timer High / Low setting: Choose an output of either 12V or 13V

Description

4H 6H

8H

AUTO

Part #:

Description:

List Price:

$99.98 $174.98

15E60BK 15E120BK

60W 120W

ON

OFF

TIMER FIG. 1

For warranty information please visit: http://www.landscapelighting.com/portal/warranty_page Para informacion de la garantia por favor visite: www.landscapelighting.com/portal/warranty_page

IS-15E60-US

129

Made with FlippingBook - professional solution for displaying marketing and sales documents online