Safety training

Control of Hazardous Energies Standard / V4 02052025

Facilitate practice for the participants in performing safe isolation and safe dissipation of pressure in a pressure system and selecting the correct test or measurement points in accordance with a hydraulic diagram and give constructive feedback to the participants´ practice throughout:

a. identify the isolation (normally the CB that supplies the electrical motor that moves the pressure pump)

b. perform the isolation (needs to be a (Safe Isolation) Authorised Person)

c.

dissipate any pressure

d.

secure the isolation against re-energisation

e.

prove absence of pressure

The participants shall:

Engage in the discussions and share understandings about:

a. The steps performed in the safe isolation and pressure system and the selection of the correct test or measurement points in accordance with a hydraulic diagram

b. The differences in the safe dissipation of pressure in a compressible pressure fluid (e.g. nitrogen) system versus a non-compressible pressure fluid (e.g. hydraulic) system

Practise performing safe isolation and safe dissipation of pressure in a pressure system and select the correct test or measurement points in accordance with a hydraulic diagram:

a. identify the isolation and ensure the isolation is carried (*If an electrical isolation is required, it must be performed by the instructor as an Electrical Qualified Person)

b.

perform the hydraulic isolation

c.

dissipate any pressure

d.

secure the isolation against re-energisation

e.

prove absence of pressure

ELEMENT 5.6 - COMPONENT REPLACEMENT IN PRESSURE SYSTEMS

Learning objectives:

Global Wind Organisation ©2025 / www.globalwindsafety.org