Where ,
RD
= Required Fall Distance Clearance (minimum anchor point height)
LL
= Length of Lanyard
DD HH
= Deceleration Distance (fall distance)
= Height of Suspended Worker
C
= Safety Factor
The value for 𝐻𝐻𝐻𝐻 is the length of the suspended worker after a fall and includes factors like the height of the person and harness stretch, to account for these variables this is set to 2.00 m. Using the value for 𝐻𝐻𝐻𝐻 (2.00 𝑚𝑚 ) , the maximum allowed values for 𝐿𝐿𝐿𝐿 (2.00 𝑚𝑚 ) & 𝐷𝐷𝐷𝐷 (1.75 𝑚𝑚 ), and the minimum allowed value for 𝐶𝐶 (1.00 𝑚𝑚 ), we get, 𝑅𝑅𝑅𝑅 = 𝐿𝐿𝐿𝐿 + 𝐷𝐷𝐷𝐷 + 𝐻𝐻𝐻𝐻 + 𝐶𝐶 and, 𝑅𝑅𝑅𝑅 =2.00 𝑚𝑚 +1.75 𝑚𝑚 +2.00 𝑚𝑚 +1.00 𝑚𝑚 , therefore , 𝑅𝑅𝑅𝑅 =6.75 𝑚𝑚 . Therefore, the GWO recommends that the anchor points used during the evacuation exercises are placed a minimum of 6.75m above the ground or any structure which a person may come into contact with, in the event of a fall.
Country Specific Equipment Standards
Equipment
Europe
North America
China
United Kingdom BS EN 361+358
ANSI/ASSP Z359.11
GB 6095 +GB 6095 W/GB 6095 Q
EN 361+358
Full Body Harness
ANSI/ASSP Z359.3
GB 24543 W/GB 24543 Q
EN 358
BS EN 358
Fall restraint lanyards
GB 24543 Z+GB/T 24538
BS EN 354 and/or BS EN 355
EN 354 and/or EN 355 ANSI/ASSP Z359.13
Fall arrest lanyard including energy absorber
Global Wind Organisation ©2023 / www.globalwindsafety.org