Technical training
Basic Technical Training / V8 2023-05-02
The instructor shall:
Show examples of and explain different types of marking and their purposes for all cable types:
a.
Cable and conductor
b.
Cabinet (diagram)
Show examples of and explain important factors when routing all cable types (inform participants to refer to work instructions for the specifics):
a.
Bending radius (why a minimum is important)
b.
Not twisted
c.
Distance between cable types and groups
d.
Fastening of cables: fixed vs flexible
e.
Cable protection tubes or edge protection
f.
Cable glands
Show examples of and explain important factors when handling fibre optic cables:
a. Handle with care due to fragility (lower it individually, do not combine with other cables when handling)
b.
Excess cable should not be cut out, but coiled
c. How to bend (coil bending radius) in accordance with work instructions
d. End protection caps are only to be removed just before the cable is connected to the individual processor
Demonstrate how to perform termination on signal cables:
a.
Mounting of ferrules
b.
Mounting in clamp and screw terminals
c.
Shield termination types
Demonstrate how to perform termination on main power cables (copper/aluminium):
a.
Mounting of cable lugs on busbar (correct torque)
b.
Mounting of cable to connectors (correct torque)
Global Wind Organisation / www.globalwindsafety.org
207 / 262
Made with FlippingBook Digital Proposal Creator