Technical training
Basic Technical Training Standard / V9 2024-06-24
Training provider: Insert image of the container for chemical being used for training
Warning! Chemical Hazard Wear required PPE stated in the Safety Data Sheet (SDS) according to the chemical in question
4.3 General Precautions When Torquing
Bolts in turbines are always tightened to specific values.
Over-tightening a bolt may lead to the bolt being damaged or failure (breaking) during turbine operation.
Under-tightening a bolt may cause bolt to loosen during turbine operation, leading to the overload of neighbouring bolts, which may subsequently fail.
It is important to follow the procedures described in this document to prevent personal injury, damage to bolts or equipment or bolt failure during turbine operation.
4.4 Approved Tightening Tools
Only calibrated tools may be used. The calibration due date must be checked with the date of the task.
Tools that are missing a label or that have exceeded the calibration date may not be used.
Training provider: insert photo of tool calibration label
Figure 4.3: An example of a tool calibration label
4.5 Reuse of Bolts and Nuts
Prior to reusing bolts and nuts, check with the company and bolt manufacturer requirements, in particular any specific relubrication requirements. Locknuts and any bolts nuts and washes that have visible damage may not be reused and must be replaced with new ones.
4.6 Lubricants
Training provider: fill in lubrication instructions in accordance with the mock-up and bolts, nuts and washers being used in training.
Global Wind Organisation / www.globalwindsafety.org