Control Techniques - Comprehensive Catalogue

WWW.CONTROLTECHNIQUES.COM

ELEVATOR DRIVE E300 DEDICATED DRIVE FOR CLASS-LEADING RIDE COMFORT

KEY FUNCTIONS

Function

Function

Creep-to-floor operation

Active thermal management

Direct-to-floor positioning

Variable speed cooling fan

Selectable speed reference

Supply loss detection

10

Start optimizer

Low DC link operation

Start locking & pre- torquing

24 Vdc backup

Selectable switching frequencies

Simple UPS connection with load direction signal

Up to 16 kHz

Skip frequency dead bans

Analogue input control

3

Analogue output control

Local/Remote keypad

2

Temperature monitoring

High resolution S-ramp

Acceleration Rates

Digital input control

8

3

Deceleration Rates

Digital I/O programmable control

8

3

Your top choice for every project. Our elevator drive solutions work for any size of building. Whether it’s a small residential building or a luxury high rise, new build or modernization projects, we make every step of the process as easy as possible from product selection to installation, setup and service.

Control mode: analogue reference

Safe Torque Off input

1

Control mode: digital binary

Relay control

1

Mechanical Brake Controller

Control mode: control word

Control mode: analouge reference over comms

Brake contact monitoring

Control mode: DCP3 & DCP4

Adjustable break delays

Traditional dual output motor contactor solution

Control mode: CANopen- Lift

Logic function control

Contactorless operation

Stator resistance compensation

Timer function control

Control Techniques’ drive range provides contactorless operation in elevator applications. Our EN81-20, EN81-50 TÜV certified Safe Torque Off (STO) function provides a highly dependable method for preventing the motor from being driven. This removes the need for both output motor contactors. The benefits of switching to a contactorless solution include: • Reduced EMC issues • Reduced acoustic noise • Improved system reliability • Simplified electrical installation • Lower system costs • Minimised cabinet space allowing machine room-less installation

Slip compensation

Limit switch control

Selectable roping ratios

Variable selector

Auto-tune static

Energy meter

Auto-tune rotating

Trip time stamping

Tunable start, run & stop gains

Trip logging

8

Zero output motor contactor solution with the E300 elevator drive

Run time log

Fast stop

Floor sensor correction

Cloning

DC injection braking

Universal feedback port on-board

Programmable braking

Speed feedback via options

122

Made with FlippingBook Publishing Software