Control Techniques - Comprehensive Catalogue

WWW.CONTROLTECHNIQUES.COM

WWW.CONTROLTECHNIQUES.COM

KEY FUNCTIONS

PUMP DRIVE F600 HIGH IP VARIANT

Function

Function

Pump multi-leader mode for up to 3 drives

Low DC link operation

Pump cascade mode for up to 4 assist pumps

Analogue inputs

2

Analogue outputs

Control mode: Induction motor operation

2

Control mode: Permanent magnet motor operation

Temperature monitoring

Pump pipe fill mode

Digital inputs

3-6

Dust and water resistant

Digital outputs

Pump dry well detection

0-3

Pump low load detection

Relays (normally open/normally closed)

2

Optional motorised potentiometer

Pump no-flow detection

Standard and High IP drives The High IP drive will already be familiar to users of the F600, with all the same features that make commissioning effortless. The Hand-Off-Auto keypad with the built-in real-time clock is still available, sealed, and the protective casing has been designed with easy servicing and usability in mind. IP65 rated enclosure. Save on installation The F600 High IP drive is enclosed in a sturdy, protective yet light casing, providing a compact solution. This not only allows easy integration in harsh environments but wall mounting close to the pump reduces installation costs, through: • No cabinet required • Shorter cable lengths • Less labour time/cost to install drive

Pump over-cycle protection

PID Control

2

Energy meter

Pump cleaning function

Hand/Off/Auto control

Trip time stamping

Pump volume monitoring

Trip logging

10

Run time log

Pump flow monitoring

Pump Wake/sleep operation

Control word control

Pump flow switch input

Auto reset

Pump assist over-cycle detection

Cloning

Auto-tune static

SD card adapter

Stop mode: Coast

SMARTCARD

Free 5 year warranty To share our confidence in the reliability of Control Techniques, drives in the F600 range are eligible for Control Techniques’ extended warranty, at no extra cost. It is a testament to our exceptional track record for reliability, giving you total peace of mind that your investment is protected and your site will continue to run uninterrupted.

Stop mode: Fast ramp

Acceleration rates

4

Deceleration rates

Motor pre-heat mode

4

Bi-polar reference

Skip frequency dead bands

Guided set-up via ‘Connect’ commissioning software

Skip frequencies

Fire Mode configurable over-ride function

Sleep Mode

Free 5 year warranty covers drives up to and including frame 7 Warranty terms and conditions apply.

HMI support

Supply loss detection