Control Techniques - Comprehensive Catalogue

WWW.CONTROLTECHNIQUES.COM

WWW.CONTROLTECHNIQUES.COM

IEC61800-3, IEC 61000-4-2, IEC 61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, IEC61000-4-11, IEC61000-6-1, IEC 61000-6-2.

Immunity Compliance

SPECIFICATION

Capable of meeting the requirements of Equipment Category C3 without external filters or line reactors. Capable of meeting the requirements of Equipment Category C1 when installed with the recommended filters (dependant on switching frequency). EN61000-6-2, EN61000-6-4, EN61000-3-2, EN61000-3-3

Emission compliance

Digitax HD

Cooling

Ultraflow TM rear venting option available

Documents: Quick Start Guide, Safety Information Booklet, Certificate of Quality. Accessories: Power input connector, Brake connector, I/O connector, 24 Vdc supply connector, cable screen bracket, 3 x M4x8 screws (motor earth, supply earth, cable screen bracket), motor connector.

Safe Torque off

Dual STO channels. SIL3/PLe compliant

Items supplied with the drive

M750 – EtherNet (multiprotocol) M751 – RS-485 M753 – EtherCAT M754 - EtherNet SI Options - EtherCAT, PROFIBUS, Ethernet, DeviceNet, CANopen, PROFINET V2

Storage temperature

-40°C to 55°C (-40°F to 131°F)

Communications

Operating temperature without de-rate

-20°C to 40°C (-4°F to 104°F)

Operating temperature with de-rate

40°C to 55°C (104°F to 131°F)

1 x Analogue input, 2 x Digital input, 2 x Digital output, 1 x Motor brake output, 7 x 0 V common, 1 x 24V user output. Pluggable control connector with push in spring connection. (Additional I/O available with SI-I/O option module). 2 x External 24 Vdc User supplied ports for control supply. Pluggable connector with screw connection.

Control I/O

200 V to 240 V ± 10% single or three phase. 380 V to 480 V ± 10% three phase.

Supply requirements

Switching frequency range

2,3,4,6,8,12,16 kHz (Factory default = 8 kHz)

Accuracy

Frequency 0.01%,Analog input 1: 11 bit plus sign. Current typical 2%.

Approvals

CE (European Union), cUL Listed (USA and Canada), KC (Korea), RCM (Australia/ New Zealand), EAC (Russian Customs Union)

Advanced 1.5 axes Motion Controller, key features include: – Real-time tasks – 250 μs cycle time – Motion profile generator – Electronic gearbox – Interpolated CAM – Homing functions – High speed position freeze

On-Board advanced motion controller

Product safety standard

EN61800-5-1

Single 7 segment display with 2 x rotary dials for node address setting. Remote keypad with Real-time clock available as option (Optional on M751).

Keypad

Functional safety (single STO function)

Independently assessed by TUV to IEC 61800-5-2 SIL 3 and EN ISO 13849-1 PL e

Parameter backup and cloning

Smartcard and SD card (using SD card adapter)

Altitude

1000 m to 3000 m (3300 ft to 9900 ft). 1% de-rate per 100 m (330 ft) above 1000 m (3300 ft)

PC Tools

‘Connect’ commissioning and cloning tool including CT Oscilloscope, Machine Control Studio for On-board PLC programming.

Humidity

95% Non-condensing at 40°C (104°F)

Warranty

2 years

Pollution

Degree 2. Dry, non-conducting pollution only

SI-EtherCAT, SI-PROFIBUS, SI-Ethernet, SI-DeviceNET, SI-CANopen, SI-PROFINET, SI-I/O, SI-Encoder (speed feedback), Remote I/O, SI-Powerlink, SI-Universal Encoder, MCi200, MCi210, SI-Apps Compact and PTi210.

Supported options

IP Rating

IP20 – Pollution degree 2

Maximum recommended continuous (random) vibration level 0.14 g r.m.s. broadband 5 to 200 Hz. Reference standard IEC60068-2-27 (bump test), IEC60068-2-64 (random vibration test), IEC60068-2-6, EN61800-5-1 (sinusoidal vibration test). Tested to Environmental Category ENV3.

Rear vent, Compact brake resistor & External brake resistors, Encoder breakout connector, KI-485 adaptor, KI compact display (supplied with M750, M753, and M754 Drives), Digitax ST retrofit brackets, SI-Option module mounting kit. External EMC filters, Fan replacement kits, Remote Keypad RTC, Multi-axis kits (24Vdc link, DC bus link, Comms link), Unidrive M to Digitax HD DC busbar adaptor kits, Capacitor Module to extend DC bus capacity and Cable grommet kit.

Vibration

Accessories

Mounting methods

Horizontal or vertical surface mounting with DIN rail alignment.

Output frequency/speed range

550 Hz (RFC-A/RFC-S); 599 Hz (Open loop)

Braking

In-built braking transistor, external resistor required (drive mountable resistor or external resistor)

Operating modes

Open-loop, RFC-A (enhanced open-loop performance), RFC-S (servo mode)

Documentation & Downloads Product documentation and PC tools available for download from: www.controltechniques.com/support

Open-loop (from cold) 150 % for 100 s, Open-loop (from 100%) 150 % for 8 s. RFC (from cold) 300% for 8 s, RFC (from 100%) 300% for 0.25 s

Overload capability

Overvoltage category

Evaluated for OVC III.

Concentrations of corrosive gases must not exceed the levels given in: Table A2 of EN 50178:1998, Class 3C2 of IEC 60721-3-3 This corresponds to the levels typical of urban areas with industrial activities and/or heavy traffic, but not in the immediate neighbourhood of industrial sources with chemical emissions.

Corrosive environments

172

173

Made with FlippingBook Publishing Software