Control Techniques - Comprehensive Catalogue

WWW.CONTROLTECHNIQUES.COM

WWW.CONTROLTECHNIQUES.COM

SPECIFICATION

Cooling

Forced cooled

Safe Torque off

None

Communications

RS-485

Digitax SF

1 x Analogue Input, 1 x Analog Ground 8 x Digital Input Programmable, 6 x Digital Output, 2 x independent digital output, 1 x Control 24V Power Input, 1 x Control Ground, 1 x I/O COM +, 1 X I/O COM-, 7 x simulated encoder output, 3 x RS485 terminals, 8 x Position Pulse Inputs

Control I/O

Items supplied with the drive

Safety information, power input connector, encoder connector

Storage temperature

-20°C to 65°C, -4°F to 149°F

Accuracy

Command pulse -paired ratio: 1/1000 < A/B < 1000,Analogue input: Single Ended ±10V

Operating temperature without de-rate

0°C to 50°C, 32°F to 122°F

On-Board user program capability

N/A

Operating temperature with de-rate

N/A

Keypad

Fixed LED keypad

Maximum supply imbalance: 2 % negative phase sequence (equivalent to 3 % voltage imbalance between phases). Input frequency 45 to 66Hz

PC Tools

‘Digitax SF Connect’ commissioning,waveform monitor and point table setup.

Supply requirements

Warranty

Switching frequency range

N/A

Supported options

N/A

Approvals

CE (European Union), UL(508C if installed in appropriate environment), KC (Korea)

Accessories

Input / Output (I/O) terminal block and cable assembly; Input / Output Interface Connector; Surge absorber / protector; EMC filter

Product safety standard

EN61800-5-1

Encoder

17-bit single or multi-turn (incremental)

Functional safety (Dual STO function)

N/A

Encoder Multi-turn count

65536

Altitude

≤1000m

Humidity

20 – 85% RH or less (Non-condensing)

Pollution

Degree 2. Dry, non-conducting pollution only

DIMENSIONS

IP Rating

IPXX – Pollution degree 2

≤5.8m/s (0.6G) 10 to 60Hz (no continuous operation allowed at resonant frequency

Vibration

W

Mounting Hole Diameter

Overall Dimensions

Mounting Dimensions

Weight

Mounting methods

Surface mount, mounting holes only

Frame Size

mm

in

mm

in

Output frequency/speed range

0 - 500Hz (50W - 750W), 0 – 250Hz (1kW – 2kW)

mm in

kg lb

HWD HWD HWHW

Braking

Mechanical brake control, no internal braking resistor but an external emergency stop braking unit can be fitted

1

160 40 130 6.3 1.57 5.12 150 30 5.91 1.18 5.5 0.22 0.7 1.54

Operating modes

Position, Velocity, Torque

H

2

160 48 130 6.3 1.89 5.12 150 30 5.91 1.18 5.5 0.22 0.8 1.76

Overload capability

350% (50W to 100W), 300% (200W to 2kW)

3

160 68 130 6.3 2.68 5.12 150 44 5.91 1.73 5.5 0.22 1 2.2

Overvoltage category

II

61.7 / 69 *

2.72 / 2.43

4

160 84 130 6.3 3.31 5.12 150

5.91

5.5 0.22 1.6 3.53

Never use the product in an environment containing explosive or flammable gases, chloride, acidic or alkaline corrosive environment such as sulfur dioxide, chlorine, ammonia and so on

Corrosive environments

* Mounting hole separation: 61.7mm at the top, 69mm at the bottom

D

Immunity Compliance

EN 61000-6-2:2005

Emission compliance

EN55011:2009+A1:2010

180

181

Made with FlippingBook Publishing Software