WWW.CONTROLTECHNIQUES.COM
WWW.CONTROLTECHNIQUES.COM
ØPH ØP
LC
Frame size 067
Motor frame size (mm)
067ED
Motor frame size (mm)
067UD
200-240
380-480
Voltage (Vrms)
Voltage (Vrms)
A
B
C
D
A
B
C
D
Frame length
Frame length
1.44
2.55 3.70 4.72
1.44
2.55 3.70 4.72
Continuous stall torque (Nm)
Continuous stall torque (Nm)
G GF
4.35 7.65 11.10 14.60
4.35 7.65 11.10 14.60
Peak torque (Nm)
Peak torque (Nm)
0.30
0.53
0.75
0.94
0.30 0.53
0.75
0.94
Standard inertia (kg cm 2 )
Standard inertia (kg cm 2 )
Winding thermal time constant (sec)
54
61
65
68
Winding thermal time constant (sec)
54
61
65
68
1.96
2.56
3.16 3.80
1.96
2.56
3.16 3.80
Standard motor weight (kg)
Standard motor weight (kg)
10
10
10
10
10
10
10
10
Number of poles
Number of poles
0.93 57
0.8 49
1.6 98
Speed 3000 (rpm)
Kt (Nm/A) = Ke (V/krpm) =
Speed 3000 (rpm)
Kt (Nm/A) = Ke (V/krpm) =
T
LA
Rated torque (Nm)
1.40 2.45 3.50 4.60
Rated torque (Nm)
1.40 2.45 3.50 4.60
LB
E
1.55
2.74 3.98 5.08
1.80 1.59 2.31 2.95
Stall current (A)
Stall current (A)
0.44
0.77
1.10 1.45
0.44
0.77
1.10 1.45
Rated power (kW)
Rated power (kW)
15.16 5.85 3.33 2.32
11.69 18.55 10.70 6.42
R (ph-ph) (Ohms)
R (ph-ph) (Ohms)
Motor Dimension
46.7
20.6 12.7 10.6
35.2 65.6 40.8 31.2
L(ph-ph) (mH)
L(ph-ph) (mH)
Fixing hole diameter
Feedback AR, CR, EM, FM, EG, FG
Mounting bolts
1
1
1
1
1
1
1
1
Flange thickness
Register length
Register diameter
Overall height
Flange square
Fixing hole PCD
Motor housing
Recommended power conn' size
Recommended power conn' size
Unbraked length Braked length LB (± 0.9) LC (± 1.0) LB (±1.0) LC (± 1.0) LA (± 0.5) T (± 0.1) N (j6) LD (± 0.3) P (± 0.3) S (H14) M (± 0.5) PH (± 0.5)
0.47 28.5
0.8 49
Speed 6000 (rpm)
Kt (Nm/A) = Ke (V/krpm) =
Speed 6000 (rpm)
Kt (Nm/A) = Ke (V/krpm) =
Rated torque (Nm)
1.3
2.2
3.1
4.0
Rated torque (Nm)
1.3
2.2
3.1
4.0
067A 067B 067C 067D
142.9 109 177.9 144 172.9 139 207.9 174 202.9 169 237.9 204 232.9 199 267.9 234
3.06
5.43 7.87 10.04
1.80 3.19 4.63 5.90
Stall current (A)
Stall current (A)
7.7
2.5
60 111.5 70
5.8
75
67
M5 mm
0.82
1.38
1.95
2.51
0.82
1.38
1.95
2.51
Rated power (kW)
Rated power (kW)
3.79
1.46 0.76 0.54
11.69 4.64 2.73 1.60
R (ph-ph) (Ohms)
R (ph-ph) (Ohms)
11.7
5.2
3.6
2.03
35.2 16.4 10.2
7.8
L(ph-ph) (mH)
L(ph-ph) (mH)
Shaft Dimension
Tapped hole thread size
1
1
1
1
1
1
1
1
Recommended power conn' size
Recommended power conn' size
Tapped hole depth
Key to shaft end
Shaft diameter
Shaft length
Key height
Key length
Key width
D(j6)
E
GA GF
G F(h9)
I
J(±1)
M5 x 0.8
14.0 Std
14
30 16 25 1.5 5
13.5 mm
19mm shaft and 90mm flange options are available. Refer to factory for more information.
ØS (x) ØM
TAPPED HOLE I ( J)
F IEC -
ØPH ØP
All data subject to +/-10% tolerance. Stall torque, rated torque and power relate to maximum continuous operation tested in a 20°C ambient at 12kHz drive switching frequency. All other figures relate to a 20°C motor temperature. Maximum intermittent winding temperature is 140°C
LC
196
G GF
Made with FlippingBook Publishing Software