WWW.CONTROLTECHNIQUES.COM
WWW.CONTROLTECHNIQUES.COM
KEY FUNCTIONS
SPECIFICATION
Mentor MP
Function
Function
Function
The drive is supplied with a Short Form Guide, a SMARTCARD, safety information, grounding bracket, power terminal shrouds (for sizes 1, 2A and 2B) and mounting feet brackets for size 1 drives.
Jog
Autotune continuous
Motorised potentiometer
Items supplied with the drive
Bi-polar reference
Catch a spinning motor
Logic function control
Storage temperature
-40°C to 55°C, -40°F to 131°F
Pre-set speeds
Stop mode: Ramp
Timer function control
8
Operating temperature without de-rate
0°C to 40°C, 32°F to 104°F
Preset timer
Stop mode: Coast
Limit switch control
Operating temperature with de-rate
0°C to 55°C, 32°F to 131°F
Skip speed
Stop mode: Fast ramp
Variable selector
3
480 V: 24 V to 480 V -20 % +10 % 575 V: 500 V to 575 V -10 % +10 % 690 V: 500 V to 690 V -10 % +10 %
Skip speed bands
Regen braking (four quadrant drives)
PID Control
Supply requirements
Local/Remote
Programmable braking
Energy meter
Switching frequency range
N/A
S-Ramp
Field economy control
Trip time stamping
CE (European Union), cUL Listed (USA and Canada), KC (Korea), RCM (Australia/ New Zealand), EAC (Russian Customs Union)
Acceleration rates
Field weakening control mode
Trip logging
8
8
Approvals
Run time log
Deceleration rates
DC contactor control
8
Product safety standard
EN61800-5-1
Pulse train frequency reference
Supply loss detection
Parallel 6, 12 and 24 pulse operation
0 - 500kHz
Functional safety (Dual STO function)
N/A
Torque reference
Low voltage operation
Control word control
Altitude
1000m – No de-rate. 1000m to 3000m - 1% de-rate/100m
Control mode: speed
Analogue input control
Auto reset
Humidity
95% Non-condensing at 40°C
Control mode: torque
Analogue output control
Cloning
Pollution
Degree 2. Dry, non-conducting pollution only
Control mode: torque control with speed override
Temperature monitoring
On-board PLC
6kB
Frame 1 - IP20 Frame 2A and 2B – IP10 Frame 2C and 2D – IP00
IP Rating
Control mode: winder (torque control)
Digital input control
Additional application parameters
64
Armature voltage drop compensation
Digital output control
Second motor set-up
Shock test: Referenced standard: BS EN 60068-2-27 Bump Test: Referenced standard: IEC 60068-2-29 Random vibration test: Referenced standard: IEC 60068-2-64 Sinusoidal vibration test: Referenced standard: IEC 60068-2-6, EN 61800-5-1:2007
Inertia compensation
Relay control
Speed feedback via options
Vibration
Auto-tune static
Mechanical brake controller
Field voltage control mode
Auto-tune rotating
Keypad button assignment
Position controller
Mounting methods
Surface mount
Output frequency/speed range
N/A
Braking
Regen braking with four quadrant drives.
Operating modes
Estimated speed (open loop), tacho feedback (closed loop) and encoder feedback (closed loop)
Overload capability
150% for 30seconds
Overvoltage category
IEC 60664-1. Evaluated for OVC III.
208
209