WWW.CONTROLTECHNIQUES.COM
WWW.CONTROLTECHNIQUES.COM
APPLICATIONS SI-APPLICATIONS PLUS SI-APPLICATIONS COMPACT
SI-Applications modules allow SyPTPro application programs to be recompiled and executed with Unidrive M700 and Digitax HD to enable rapid and simple upgrade to users. Applications comprising networked drives with SM-Applications using CTNet or CTSync for real- time control can be quickly replaced with Unidrive M and Digitax HD and the SI-Applications module without any compromise to system performance.
Features include:
Terminal Descriptions
• Enhanced high speed dedicated microprocessor • 384 kB Flash memory for user program • 80 kB user program memory • EIA-RS485 port offering ANSI, Modbus-RTU follower and master and Modbus-ASCII follower and master protocols • CTNet high speed network connection offering up to 5 Mbit/s data rate • Two 24 V digital inputs • Two 24 V digital outputs • Task based programming system for real-time control • CTSync distributes a master position to multiple drives on a network. Hardware synchronization of speed, position and torque loops achieving a time base of 250 μs
1
2
3
4
5
6
7
8
9
10
11
12
13
Terminal
Function
Description
1
0 V SC
0 V connection for EIA-RS485 port
2
/RX
EIA-RS485 Receive line (negative). Incoming
3
RX
EIA-RS485 Receive line (positive). Incoming
4
/TX
EIA-RS485 Transmit line (negative). Outgoing
5
TX
EIA-RS485 Transmit line (positive). Outgoing
6
CTNET A
CTNet data line
7
CTNET Shield
Shield connection for CTNet
8
CTNET B
CTNet data line
9
0 V
0 V connection for digital I/O
10
DIO
Digital input 0
11
DI1
Digital input 1
SI-Applications Plus Can be used with Unidrive M only in option slot 3
SI-Applications Compact Can be used with Unidrive M and Digitax HD in any option slot
12
DO0
Digital output 0
13
DO1
Digital output 1