Control Techniques - Comprehensive Catalogue

WWW.CONTROLTECHNIQUES.COM

WWW.CONTROLTECHNIQUES.COM

UNIDRIVE M700

Quick Start

I just received my first Unidrive M400, how do I get it running with my motor?

https://youtu.be/jRVi2ObQ9Ok

Question

Answer

I just received my first Unidrive M300, how do I get it running with my motor?

https://youtu.be/rEqJjvG48EY

General Topics

I just received my first Unidrive M200, how do I get it running with my motor?

https://youtu.be/ZKhVcH9hN7E

How do I configure the digital IO on my Unidrive M or Commander C drive?

https://youtu.be/d9OjecE2zYw

https://youtu.be/QzQacmfRQJI https://youtu.be/BEi29-ILzu8

I just received my first C200, how do I get it running with my motor?

https://youtu.be/mnZo15UksCo https://youtu.be/laQTufDIUPc

I just received my first C300, how do I get it running with my motor?

How do I use the buttons on a KI Keypad, and what are the symbols that appear on the display?

Drive Software

1. Escape button 2. Start reverse (Auxiliary button) 3. Start forward 4. Navigation keys (x4) 5. Stop/Reset (red) button 6. Enter Button NOTE: The red stop button is also used to reset the drive.

How can I transition my M300 drive to a C300 drive using Connect software?

https://youtu.be/8A-8LfbNKY0

Open loop mode The drive applies power to the motor frequencies varied by the user. The motor speed is a result of the output frequency of the drive and slip due to the mechanical load. The drive can improve the speed control of the motor by applying the slip compensation. The performance at low speed depends on whether V/F mode or open loop vector mode is selected. Open loop vector mode The voltage applied to the motor is directly proportional to the frequency except at low speed where the drive uses motor parameters to apply the correct voltage to keep the flux constant under varying load conditions. Fixed V/F mode The voltage applied to the motor is directly proportional to the frequency except at low speed where the voltage boost is provided which is set by the user. This mode can be used for multi-motor applications. Typically 100% torque is available down to 4 Hz for a Hz motor. Quadratic V/F mode The voltage applied to the motor is directly proportional to the square of the frequency except at low speed where the voltage boost is provided which is set by the user. The mode can be used for running fan or pump applications with quadratic load characteristics or for multi-motor applications. This mode is not suitable for applications requiring a high starting torque.

What kind of torque performance can I expect from my Unidrive M700 in Open Loop mode?

Yes,you can apply a 24 VDC power to the drive to power the drive processor (please see user manual for the specific drive). This will allow you to save parameters and files from the drive in the event of a power stage failure, or so that the drive can be programmed before it is installed in the equipment panel.

Is it possible to program or setup a drive parameter file without line voltage on the drive?

285