SPECIFICATION
Power & Control
Mounting & Environment continued Cooling
100 V drive: 100 V to 120 V ±10 % 200 V drive: 200 V to 240 V ±10 % 400 V drive: 380 V to 480 V ±10 % 575 V drive: 500 V to 575 V ±10 % 690 V drive: 500 V to 690 V ±10 % Maximum supply imbalance: 2 % negative phase sequence (equivalent to 3 % voltage imbalance between phases)
Integral cooling fan
Altitude
≤3000 m (≤1000 m no de-rate; 1000 m to 3000 m derate 1 % every 100 m)
Supply Requirements
Humidity
95 % non-condensing at 40 °C / 104 °F - EN61800-2(3k3)
Pollution
Pollution degree 2 - dry, non-conducting pollution only
Input Displacement Power Factor
0.97
Reference standard IEC60068-2-27, IEC60068-2-29 bump test, IEC60068-2-64 random vibration test, IEC60068-2-6, EN61800-5-1 sinusoidal vibration test. Tested to Environmental Category ENV3
Vibration
Phase
1 and 3 (model dependent)
Mechanical Shock
Tested in accordance with IEC 60068-2-27 and IEC 60068-2-29
Power Range
0.25 to 132 kW / 0.33 to 200 hp
Input Frequency Range
45 to 66 Hz
Frame 1 to 4 – Surface mount via mounting holes or DIN Rail mount Frame 5 to 9 – Surface mount via mounting brackets or through-panel mount via through-panel mounting kit
Mounting Methods
Output Frequency/Speed Range
0 to 550 Hz
Size 1 - 4: 0.667, 1, 2, 3, 4, 6, 8 12 & 16 kHz Size 5 - 9: 2, 3, 4, 6, 8 12 & 16 kHz (Factory default = 3kHz)
Mounting Clearance
0 mm either side, 100 mm above and below
Switching Frequency
Overvoltage Category
Category III (IEC/EN/KN/UL 61800-5-1)
Heavy Duty Overload Capability
150 % for 60 s (open loop mode), 180 % for 3 s (RFC-A mode)
Corrosive Environments
EN 60721-3-3 ISO9223 Class C3
Linear V to F Square V to F
75 m Frame 1 100 m Frames 2 to 4 200 m Frames 5 to 6 250 m Frames 7 to 9
Dynamic V to F Set Point V to F Stator Resistance Compensation RFC-A (enhanced open-loop performance)
Operating Modes
Maximum Motor Cable Length
Standards
Coast, Ramp, Ramp & DC Injection Braking, DC Injection Braking with 0 Hz detect, Timed DC Injection Braking Built-in braking transistor, external resistor required
Stopping Modes
CE (European Union), cUL Listed (USA and Canada), DNV (marine applications), KC (Korea), RCM (Australia/ New Zealand), EAC (Russian Customs Union), UKCA (United Kingdom), C-Tick (Australia)
Approvals
Communication & Interfaces
Modbus RTU, EtherCAT, PROFIBUS, Ethernet, DeviceNET, CANopen, PROFINET, POWERLINK (all available with AI/SI-options)
E171230
Communications
Product Safety Standards
IEC/EN/KN/UL 61800-5-1, CSA C22.2 No.274, GB12668.501-2013
Fixed LED keypad Remote IP66 Keypad (available as an accessory) Remote IP66 RTC Keypad (available as an accessory) HMI (available as an accessory) Connect (PC commissioning & cloning tool) Machine Control Studio for on-board PLC programming
C300 models only: The Safe Torque Off (STO) function may be used as a safety component of a machine. Type examination certificates by TÜV Rheinland:
Keypads
Frame sizes 1 - 4: No. 01/205/5383.03/18 Frame sizes 5 - 9: No. 01/205/5387.02/18 Functional safety parameters: EN ISO 13849-1 - Cat 4, PLe EN61800-5-2/EN62061/IEC 61508 - SIL 3 UL functional safety approval: FSPC E171230
TÜV
User Software Tools (Free To Download)
Inputs & Outputs
2 x Analogue input Possible settings: 0-10 V, 0-20 mA, 4-20 mA (No Alarm), 4-20 mA (Alarm), 4-20 mA (Error)
IEC/ EN 61800-3 Immunity and Emissions EN 61000-6-2: Immunity for industrial environments EN 61000-6-4: Emissions for industrial environments
Analogue
1 x Analogue output Possible settings: 0-10 V
Product EMC Standards
EN 61000-3-2: Harmonic current emissions An EMC data sheet is available on request
3 x Digital inputs (1 frequency input) 1 x Digital input / output programmable 1 x Digital input / output programmable (can be used as a frequency or PWM output to represent analogue value)
Digital
RoHS
Complies with the Restriction of Hazardous Substances Directive (2011/65/EU)
Digital Input Logic
Positive
Immunity Compliance
Second environment (Industrial)
Relay
1 x Relay (single pole, double throw relay)
ISO
Manufacturing facilities comply with ISO 9001:2015 and ISO 14001
Accuracy
Frequency 0.02%,Analogue input 1: 11 bit plus sign,Analogue input 2: 11 bit. Current typical 2%.
Warranty Warranty
3 x Analogue inputs (default) / Digital inputs programmable 4 x Digital input / output programmable 1 x Digital input 2 x Relays
5Years (warranty terms and conditions apply)
Extra I/O with SI-I/O Option Module (Available as an Accessory)
Accessories
Remote Interfaces
Remote keypad IP66, Remote keypad RTC, HMI
Mounting & Environment
IP20 Conduit Box UL Type 1 ingress protection (available as an accessory)
Filters & Cables
External EMC filters, CT communications cable
IP Rating
AI-485 24 V Adaptor, SI-EtherCAT, SI-PROFIBUS, SI-Ethernet , SI-DeviceNET, SI-CANopen, SI-PROFINET , SI-POWERLINK, SI-Encoder
Storage Temperature
-40 °C to 60 °C (-4 °F to 140 °F)
Communication & Feedback, SI-Options
Operating Temperature Without De-Rate
-20 °C to 40 °C (-4 °F to 104 °F)
-20 °C to 60 °C (-4 °F to 140 °F) Frames 1 to 4 -20 °C to 55 °C (-4 °F to 131 °F) Frames 5 to 9
Operating Temperature with De-Rate
50