FUNCTIONALITY
Modbus RTU Communications (available with AI-485 Adaptor) Control Word Control
AI-Back-up Adaptor AI-Smart Adaptor
Back-up & Cloning
Conduit Box
For UL Type 1 ingress protection
Cloning
Protection Conformal Coating
Serial Baud Rate
600 to 115000 bps
100 % Coverage
100 V models: 175 Vdc 200 V models: 175 Vdc 400 V models: 330 Vdc 575 V models: 435 Vdc 690 V models: 435 Vdc
Modbus RTU Protocol
8.2NP, 8.1NP, 8.1EP, 8.1OP
On Board PLC
DC Bus Undervoltage Error Level
User Memory Space
30 KB
Machine Control Studio • CODESYS based
Frame sizes 1 - 4:
• Included programming languages: ladder diagram, structure text, function block diagram, instruction list, sequential function chart, continuous function chart • Function block libraries • On-line monitoring of program variables with user defined watch windows • Support for on-line change of program
100 V models: 510 Vdc 200 V models: 510 Vdc 400V models: 870 Vdc
User Software Tools (Free to Download)
DC Bus Overvoltage Error Level
Frame size 5 - 9:
200V models: 415 Vdc 400 V models: 830 Vdc 575 V models: 990 Vdc 690 V models: 1190 Vdc
Pre-set Programs (Available on Request)
Unbalanced Load Detection (Laundry Application)
Reference
Drive Overload Error
Programmable: Default settings: 180% for 3s, 150% for 60s
4 (Selectable: Analogue Ref. 1, Analogue Ref. 2, Pre-set Frequency Ref., Keypad Ref.)
Selectable References
Instantaneous Overcurrent Error/Limit
220% of rated motor current
Phase Loss Error
DC Bus Ripple Threshold Exceeded
Jog Reference
Control Board Over Temperature, Inverter Model Temperature, Inverter Thermistor Temperature, Drive heatsink temperature exceeds 95°C (203°F)
Overtemperature Error
Up / Down % Reference (Motorised Pot)
Short Circuit Error
Protection against output phase-to-phase fault
Bi-Polar Reference
Ground Fault Error
Protection against output phase-to-ground fault
Pre-set Speeds
8
Motor Thermal Protection
Electronically protects the motor from over-heating due to loading conditions
Pre-set Timer
Keep Running
Parameter set to avoid errors and machine downtime (needs to be configured)
Skip Frequencies
3
Dedicated Thermistor Input
Avoid downtime or machine damage due to overheated motor
General Items supplied with the drive
Skip Frequencies Dead Band
Step-By-Step Guide, Safety Information, Grounding bracket (Frames 1 to 4), Surface mounting brackets (frame 5 to 9)
Local/Remote
S-Ramp
Acceleration Rates
8
Deceleration Rates
8
Frequency Input Reference (Pulse Train)
0 Hz to 100 kHz
Run Reverse
Torque Reference
Application Specific
PID Controller
PI Control
PID Feedforward
PID Threshold Detector
PID Slew Rate