FUNCTIONALITY

Modbus RTU Communications (available with AI-485 Adaptor) Control Word Control

AI-Back-up Adaptor AI-Smart Adaptor

Back-up & Cloning

Conduit Box

For UL Type 1 ingress protection

Cloning

Protection Conformal Coating

Serial Baud Rate

600 to 115000 bps

100 % Coverage

100 V models: 175 Vdc 200 V models: 175 Vdc 400 V models: 330 Vdc 575 V models: 435 Vdc 690 V models: 435 Vdc

Modbus RTU Protocol

8.2NP, 8.1NP, 8.1EP, 8.1OP

On Board PLC

DC Bus Undervoltage Error Level

User Memory Space

30 KB

Machine Control Studio • CODESYS based

Frame sizes 1 - 4:

• Included programming languages: ladder diagram, structure text, function block diagram, instruction list, sequential function chart, continuous function chart • Function block libraries • On-line monitoring of program variables with user defined watch windows • Support for on-line change of program

100 V models: 510 Vdc 200 V models: 510 Vdc 400V models: 870 Vdc

User Software Tools (Free to Download)

DC Bus Overvoltage Error Level

Frame size 5 - 9:

200V models: 415 Vdc 400 V models: 830 Vdc 575 V models: 990 Vdc 690 V models: 1190 Vdc

Pre-set Programs (Available on Request)

Unbalanced Load Detection (Laundry Application)

Reference

Drive Overload Error

Programmable: Default settings: 180% for 3s, 150% for 60s

4 (Selectable: Analogue Ref. 1, Analogue Ref. 2, Pre-set Frequency Ref., Keypad Ref.)

Selectable References

Instantaneous Overcurrent Error/Limit

220% of rated motor current

Phase Loss Error

DC Bus Ripple Threshold Exceeded

Jog Reference

Control Board Over Temperature, Inverter Model Temperature, Inverter Thermistor Temperature, Drive heatsink temperature exceeds 95°C (203°F)

Overtemperature Error

Up / Down % Reference (Motorised Pot)

Short Circuit Error

Protection against output phase-to-phase fault

Bi-Polar Reference

Ground Fault Error

Protection against output phase-to-ground fault

Pre-set Speeds

8

Motor Thermal Protection

Electronically protects the motor from over-heating due to loading conditions

Pre-set Timer

Keep Running

Parameter set to avoid errors and machine downtime (needs to be configured)

Skip Frequencies

3

Dedicated Thermistor Input

Avoid downtime or machine damage due to overheated motor

General Items supplied with the drive

Skip Frequencies Dead Band

Step-By-Step Guide, Safety Information, Grounding bracket (Frames 1 to 4), Surface mounting brackets (frame 5 to 9)

Local/Remote

S-Ramp

Acceleration Rates

8

Deceleration Rates

8

Frequency Input Reference (Pulse Train)

0 Hz to 100 kHz

Run Reverse

Torque Reference

Application Specific

PID Controller

PI Control

PID Feedforward

PID Threshold Detector

PID Slew Rate

52