WWW.CONTROLTECHNIQUES.COM
WWW.CONTROLTECHNIQUES.COM
CONNECTIONS
DIMENSIONS
Commander C200/C300 Dimensions
Overall Dimensions
Mounting Dimensions
Mounting Hole Dia.
Weight
Frame Size
mm
in
mm
in
mm in
kg
lb
H
W D
H W D
H
W H
W
Typical Power Connetions
Default Control Connections
1
160
75 130 6.30 2.95 5.1 143
53
5.7
2.08
5.0
0.20 0.75 1.65
2
205
75 150 8.07 2.95 5.9 194
55
7.63 2.17
5.0
0.20
1.3
3.0
3
226
90 160 8.90 3.54 6.3 215
70.7
8.46 2.80
5.0
0.20
1.5
3.3
4
277
115 175 10.90 4.50 6.9 265
86
10.43 3.40
6.0
0.23 3.13
6.9
5
391
143 200 15.39 5.63 7.87 375
106
14.76 4.17
6.5
0.26
7.4
16.3
6
291
210 227 15.39 8.27 8.94 378
196
14.88 7.72
7.0
0.28 14.0 30.9
7
557
270 280 21.93 10.63 11.02 538
220
21.18 8.66
9.0
0.35 28.0 61.7
8
804
310 290 31.65 12.21 11.42 884
259
30.87 10.20 9.0
0.35 52.0 114.6
9A
1069 310 290 42.09 12.21 11.42 1051
259
41.38 10.20 9.0
0.35 46.0 101.4
9E
1108 310 290 43.62 12.21 11.42 1090
259
42.91 10.20 9.0
0.35 66.5 146.6
Documentation & Downloads
PRODUCT CODES
Product documentation and PC tools available for download from: www.controltechniques.com/support
C200- 03 4
00073
A - 101 00 AB100
Model: C200 – The lead product for Commander C range C300 – As C200 + dual STO
Frame Size 1 to 9
Current Rating:
CT Reserved
Product Variant:
Heavy Duty current rating x 10
AB100- Standard
Voltage Rating: 1: 100 V drive (100 V to 120 V ±10 %) 2: 200 V drive (200 V to 240 V ±10 %) 4: 400 V drive (380 V to 480 V ±10 %) 5: 575 V drive (500 V to 575 V ±10 %) 6: 690 V drive (500 V to 690 V ±10 %)
Regional Default Setting: 00 – 50 Hz
Drive Format: A – AC in AC out
01 – 60 Hz
*E – AC in AC out, External line reactor
56