WWW.CONTROLTECHNIQUES.COM
WWW.CONTROLTECHNIQUES.COM
FUNCTIONALITY
Mounting & Environment continued Vibration
Tested to IEC 60068-2-6
Mounting Methods
Surface mount, click on/click off DIN rail mount
Marshal
Mounting Clearance
0 mm either side, 45 mm above and below (100 mm above and below for frame 1 drives ≤0.25 kW / 0.33 hp)
Overvoltage Category
Category III (IEC/EN/KN/UL 61800-5-1)
Offline Programming
Program the drive while it is still in the box
Corrosive Environments
EN 60721-3-3 ISO9223 Class C3
Cloning
Clone parameter sets from one drive to another
Maximum Motor Cable Length
50 m (All variants)
Faststart
Guided commissioning and motor rotation verification test
Standards Approvals
Guided Diagnostics
Easy fault finding
CE, UKCA, cUL, C-Tick, EAC, KC
Parameter File Storage
Save parameter files to the device or cloud for future use
E171230
Share Project Configuration
Share to colleagues or to Control Techniques Technical Support for diagnostics
Product Safety Standards
IEC/EN/KN/UL 61800-5-1, CSA C22.2 No.274, GB12668.501-2013,
Pdf Parameter Set
Useful for sharing parameter sets for quick review
IEC/EN/KN 61800-3 Adjustable speed electrical power drive systems, Part 3: EMC requirements and specific test methods
Product Emc Standards
Wiring Diagram
Automatically generate a printable pdf of a custom wiring diagram for your installation
GB12668.3-2012
Non-Default Parameter
Show the parameters that have been changed from their default setting
Immunity Compliance
Second environment (Industrial)
Favourite Parameters
Favourite parameters visited often
Category C3 (internal filters only) Category C1 & C2 (external EMC filters) Category C1,(internal filters only, for selected 1 Φ 200 V variants)
Emission Compliance
Guides And Manuals
Quick access to drive documentation
Modbus RTU Communications
Logic function control
EN61000-6-1: Generic immunity standard for residential, commercial and light industrial environments EN 61000-6-2: Generic immunity standard for industrial environments
Generic Immunity Compliance
Control Word Control
Cloning
Generic Emission Compliance
EN 61000-6-4: Generic emission standard for industrial environments
Serial Baud Rate
600 to 115200 bps
Emission Compliance for Motor Cable Length up to 50 m Emission Compliance for Motor Cable Length up to 20 m
C2 with an external filter
Modbus Rtu Protocol
8.2NP, 8.1NP, 8.1EP, 8.1OP
C1 with an external filter C3 without a filter
Reference
Selectable References
4
Emission Compliance for Motor Cable Length up to 5 m
C1 only for drive variants with internal C1 filter (S100-xxxx1)
Jog Reference
Warranty Warranty
Up / Down % Reference (Motorised Pot)
5Years (warranty terms and conditions apply)
Bi-Polar Reference
Accessories Remote Interfaces
Preset Speeds
4
Remote keypad IP66, HMI
Skip Frequencies
1
Filters & Cables
EMC filter, Cable management bracket, CT comms cable
Skip Frequencies Dead Band
Environmental Protection
Fibre filter
Protection Conformal Coating
Local/Remote
100 % Coverage nano-coating
S-Ramp
100 V Drives= 175 V 200 V Drives = 175 V 400 V Drives = 330 V 100 V Drives = 400 V 200 V Drives = 400 V 400 V Drives = 800 V
Acceleration Rates
2
DC Bus Undervoltage Error Level
Deceleration Rates
2
Frequency Input Reference (Pulse Train)
0 Hz to 100 kHz
DC Bus Overvoltage Error Level
Run Reverse
Instantaneous Overcurrent Error/Limit
150 % Motor Rated Current (Programmable)
Phase Loss Error
DC Bus Ripple Threshold Exceeded
Overtemperature Error
Control Board Over Temperature, Inverter Model Temperature, Inverter Thermistor Temperature
Short Circuit Error
Protection against output phase-to-phase fault.
Motor Thermal Protection
Electronically protects the motor from over-heating due to loading conditions
Fire Mode
Run at a set frequency ignoring selected errors
Keep Running
Parameter defaults set to avoid errors and machine downtime.
64
65
Made with FlippingBook Publishing Software