Control Techniques - Comprehensive Catalogue

WWW.CONTROLTECHNIQUES.COM

WWW.CONTROLTECHNIQUES.COM

Optional External Filters*

Variants with C1 built-in EMC filter

Motor Shaft Power (kW)

Motor Shaft Power (hp)

Commander S Optional External EMC Filters Product Code

Commander S Optional External Low Leakage Filter Product Code

Alternative Commander C Filter** Product Code

Commander S Product Code

Heavy Duty

Internal EMC Filter Performance

Product Code

Input Phases

Frame Size

100/120 Vac +/-10%

Max Cont. Current (A)

Motor Shaft Power (kW) Motor Shaft Power (HP)

S100-01113-0A0000

0.18

0.25

4200-0026

4200-0038

200/240 Vac +/-10%

S100-01123-0A0000

0.25

0.33

4200-0026

4200-0038

S100-02S11-0A0000

1

02

C1

1.2

0.18

0.25

S100-01133-0A0000

0.37

0.50

4200-0026

4200-0038

S100-02S21-0A0000

1

02

C1

1.4

0.25

0.33

S100-03113-0A0000

0.55

0.75

4200-0028

4200-0039

S100-02S31-0A0000

1

02

C1

2.2

0.37

0.5

S100-03123-0A0000

0.75

1

4200-0028

4200-0039

S100-02S41-0A0000

1

02

C1

3.2

0.55

0.75

S100-03133-0A0000

1.10

1.50

4200-0028

4200-0039

S100-02S51-0A0000

1

02

C1

4.2

0.75

1

200/240 Vac +/-10%

S100-02S61-0A0000

1

02

C1

6

1.1

1.5

S100-01S13-0A0000

0.18

0.25

4200-0026

4200-0038

4200-1000

S100-02S71-0A0000

1

02

C1

6.8

1.5

2

S100-01213-0A0000

0.18

0.25

4200-0031

4200-0040

4200-2003

S100-01S23-0A0000

0.25

0.33

4200-0026

4200-0038

4200-1000

Note: The listed ordering codes are for 50 Hz default setting. For 60 Hz default setting change the ending digits from 0A0000 to 0B0000.

S100-01223-0A0000

0.25

0.33

4200-0031

4200-0040

4200-2003

S100-01S33-0A0000

0.37

0.50

4200-0026

4200-0038

4200-1000

S100-01233-0A0000

0.37

0.50

4200-0031

4200-0040

4200-2003

S100-01S43-0A0000

0.55

0.75

4200-0026

4200-0038

4200-1000

S100-01243-0A0000

0.55

0.75

4200-0031

4200-0040

4200-2003

S100-01S53-0A0000

0.75

1

4200-0026

4200-0038

4200-1000

S100-01253-0A0000

0.75

1

4200-0031

4200-0040

4200-2003

4200-0026 (1 ph) 4200-0032 (3 ph) 4200-0026 (1 ph) 4200-0032 (3 ph) 4200-0028 (1 ph) 4200-0033 (3 ph)

4200-0038 (1 ph) 4200-0040 (3 ph|) 4200-0038 (1 ph) 4200-0040 (3 ph) 4200-0039 (1 ph) 4200-0042 (3 ph)

4200-2001 (1 ph) 4200-2003 (3 ph) 4200-2001 (1ph) 4200-2003 (3ph) 4200-4000 (1ph) 4200-4002 (3ph)

S100-01D63-0A0000

1.10

1.50

S100-01D73-0A0000

1.50

2

S100-03D13-0A0000

2.20

3

380/480 Vac +/-10%

S100-02413-0A0000

0.37

0.50

4200-0034

4200-0041

4200-2005

S100-02423-0A0000

0.55

0.75

4200-0034

4200-0041

4200-2005

S100-02433-0A0000

0.75

1

4200-0034

4200-0041

4200-2005

S100-02443-0A0000

1.10

1.50

4200-0034

4200-0041

4200-2005

S100-02453-0A0000

1.50

2

4200-0034

4200-0041

4200-2005

S100-02463-0A0000

2.20

3

4200-0034

4200-0041

4200-2005

S100-03413-0A0000

3

3

4200-0033

4200-0042

4200-3008

S100-03423-0A0000

4

5

4200-0033

4200-0042

4200-3008

*Commander S100 variants fitted with C3 EMC filter comply with IEC 61800-3 second environment. An additional external filter is required for Commander S100 variants fitted with C3 EMC filter to meet the higher requirements of IEC 61000‑6‑4 and IEC 61800‑3 first environment. The requirements of IEC 61000-6-4 and IEC 61800-3 first environment are met by Commander S100 variants fitted with C1 EMC filter without additional filtering.

**The alternative Commander C Filter does not support footprint mounting of the Commander S but does meet the levels specified in Table 10-4 with the following exception: The S100-01243 drive does not meet C1 at 4 kHz with a 20 m cable length.

70

71

Made with FlippingBook Publishing Software