Optional External Filters*
Variants with C1 built-in EMC filter
Motor Shaft Power (kW)
Motor Shaft Power (hp)
Commander S Optional External EMC Filters Product Code
Commander S Optional External Low Leakage Filter Product Code
Alternative Commander C Filter** Product Code
Commander S Product Code
Heavy Duty
Internal EMC Filter Performance
Product Code
Input Phases
Frame Size
100/120 Vac +/-10%
Max Cont. Current (A)
Motor Shaft Power (kW) Motor Shaft Power (HP)
S100-01113-0A0000
0.18
0.25
4200-0026
4200-0038
200/240 Vac +/-10%
S100-01123-0A0000
0.25
0.33
4200-0026
4200-0038
S100-02S11-0A0000
1
02
C1
1.2
0.18
0.25
S100-01133-0A0000
0.37
0.50
4200-0026
4200-0038
S100-02S21-0A0000
1
02
C1
1.4
0.25
0.33
S100-03113-0A0000
0.55
0.75
4200-0028
4200-0039
S100-02S31-0A0000
1
02
C1
2.2
0.37
0.5
S100-03123-0A0000
0.75
1
4200-0028
4200-0039
S100-02S41-0A0000
1
02
C1
3.2
0.55
0.75
S100-03133-0A0000
1.10
1.50
4200-0028
4200-0039
S100-02S51-0A0000
1
02
C1
4.2
0.75
1
200/240 Vac +/-10%
S100-02S61-0A0000
1
02
C1
6
1.1
1.5
S100-01S13-0A0000
0.18
0.25
4200-0026
4200-0038
4200-1000
S100-02S71-0A0000
1
02
C1
6.8
1.5
2
S100-01213-0A0000
0.18
0.25
4200-0031
4200-0040
4200-2003
S100-01S23-0A0000
0.25
0.33
4200-0026
4200-0038
4200-1000
Note: The listed ordering codes are for 50 Hz default setting. For 60 Hz default setting change the ending digits from 0A0000 to 0B0000.
S100-01223-0A0000
0.25
0.33
4200-0031
4200-0040
4200-2003
S100-01S33-0A0000
0.37
0.50
4200-0026
4200-0038
4200-1000
S100-01233-0A0000
0.37
0.50
4200-0031
4200-0040
4200-2003
S100-01S43-0A0000
0.55
0.75
4200-0026
4200-0038
4200-1000
S100-01243-0A0000
0.55
0.75
4200-0031
4200-0040
4200-2003
S100-01S53-0A0000
0.75
1
4200-0026
4200-0038
4200-1000
S100-01253-0A0000
0.75
1
4200-0031
4200-0040
4200-2003
4200-0026 (1 ph) 4200-0032 (3 ph) 4200-0026 (1 ph) 4200-0032 (3 ph) 4200-0028 (1 ph) 4200-0033 (3 ph)
4200-0038 (1 ph) 4200-0040 (3 ph|) 4200-0038 (1 ph) 4200-0040 (3 ph) 4200-0039 (1 ph) 4200-0042 (3 ph)
4200-2001 (1 ph) 4200-2003 (3 ph) 4200-2001 (1ph) 4200-2003 (3ph) 4200-4000 (1ph) 4200-4002 (3ph)
S100-01D63-0A0000
1.10
1.50
S100-01D73-0A0000
1.50
2
S100-03D13-0A0000
2.20
3
380/480 Vac +/-10%
S100-02413-0A0000
0.37
0.50
4200-0034
4200-0041
4200-2005
S100-02423-0A0000
0.55
0.75
4200-0034
4200-0041
4200-2005
S100-02433-0A0000
0.75
1
4200-0034
4200-0041
4200-2005
S100-02443-0A0000
1.10
1.50
4200-0034
4200-0041
4200-2005
S100-02453-0A0000
1.50
2
4200-0034
4200-0041
4200-2005
S100-02463-0A0000
2.20
3
4200-0034
4200-0041
4200-2005
S100-03413-0A0000
3
3
4200-0033
4200-0042
4200-3008
S100-03423-0A0000
4
5
4200-0033
4200-0042
4200-3008
*Commander S100 variants fitted with C3 EMC filter comply with IEC 61800-3 second environment. An additional external filter is required for Commander S100 variants fitted with C3 EMC filter to meet the higher requirements of IEC 61000‑6‑4 and IEC 61800‑3 first environment. The requirements of IEC 61000-6-4 and IEC 61800-3 first environment are met by Commander S100 variants fitted with C1 EMC filter without additional filtering.
**The alternative Commander C Filter does not support footprint mounting of the Commander S but does meet the levels specified in Table 10-4 with the following exception: The S100-01243 drive does not meet C1 at 4 kHz with a 20 m cable length.
70