Arable
Possible problems
This type of system is normally very reliable, assuming the display has power and the wiring/connections are good. Common problems, however, are as follows:
• the float on the rod gets caught on something in the tank and does not float on the top of the liquid • the operator accidentally recalibrates the system and enters the incorrect level • poor cleaning, for example when a pod sticker has been used and the float sticks to the bottom of the tank.
Automatic tank-fill system
What are its uses?
The automatic tank-fill system saves time, eases the filling process and prevents overfilling.
How does it work?
This system is the next step on from the electronic sight gauge. Electric filling valves are added to start and stop the fill.
The sight gauge shows a live tank content, allowing the operator to enter the total amount required, the system will take into account any volume left in the tank.