Thread Tolerance
-In the thread deviation view both a numeric and graphical result will be displayed for each coefficient that has been toleranced.
-The numeric value represents the actual deviation from nominal for a given coefficient.
NOTE: The nominal value for some coefficients does not fall within the upper and lower limit. -The graphical deviation display is a fence graphic that indicates the position of the actual thread result within the upper and lower limit for the coefficient. The middle of the fence graphic represents the middle of the range from the lower limit to the upper limit.
-The thread feature itself will fail if any one of the toleranced coefficients fails. Individual coefficients that fail will be displayed in red.
Thread Annotation
-Thread features can be annotated in the part view or the live video view by the same method as other feature types. Select the annotation button and then drag from the thread feature to add the annotation coefficients based on the selection from the annotation coefficient list.