Mold Components 2025

HYDRAULIC UNSCREWING DEVICE Calculations/Specifications

Thread Lead = 1/(Threads per inch) = 1/Pitch = Inches/Thread Thread Length = Length of threads to be removed from the cap A. Stroke (Inches) NOTE: Limit switches should be used if possible to limit full cylinder travel. This will extend the seal life inside the hydraulic cylinder.

a) Required revolutions (thread core) Thread Length =

+ Safety (.5 revolutions minimum)

Thread Lead b) 1. Required stroke – Inches = Gear Pitch Diameter x π x Required Revolutions If required stroke is too long, a cogwheel transmission should be used. 2. Length of Rack b 2 = x + y + b 1 c) Stripper stroke (Inches) = Cylinder Stroke – Required Rack Stroke

ATTACHED TO MOLD

STATIONARY HYDRAULIC CYLINDER

MOVING RACK

BACK VIEW, THREADED CORES EXTEND FROM OTHER SIDE OF THE SPUR GEAR

PITCH CIRCLE – PITCH DIA. x PI SPUR GEAR

Y = MAXIMUM PRODUCT SPACING (MULTIPLE CAVITIES CAN BE LOCATED BETWEEN)

> PITCH DIA. PERIMETER x REVOLUTIONS b 1

X

REQUIRED STROKE TO UNSCREW CAPS

UNUSABLE SPACE

b 2