SAFETY
FLOOR SUPPORT PLATE
T inst
* The floor on which the racking system rests must be checked in terms of suitability for withstanding the pressure and the puncturing (drilling) stress applied by the shel- ving system itself and the pulling strength exerted by the anchor. **The area must not be submitted to any other force.
The support plate is designed to distribute the pressure applied on the floor by the Side PANEL. A technical data sheet supplied by FAMI is useful to check the suitability of the floor intended for racking system installation.
t fix
h1
h nom
H
recommended anchor strength
5,6 kN
anchor diameter
Ø10 mm
concrete hole diameter
Ø10 mm
h 1 70 mm
minimum hole depth
h nom 50 mm t fix 20 mm T inst 25 NM
minimum installation depth
max adjustable thickness
max tightening torque
17.5
113
C
min floor thickness for anchor plug fixing*
A
H: 100 mm
Ø18
B
51
min anchor distance from the edge of the floor
B: 50 mm
Floor edge
anchor strength application area**
Anchor strength application area
A: 75 mm
B
min upright distance from the edge of the floor
C: 0 mm
1184