Metal Stud Partition system type - GypWall Product Substantiation Report (PSR) reference – A206230 Performance characteristics Partition Fire Resistance (BS 476): Partition Laboratory Sound Resistance (BS EN 717):

60 minutes

53 R w Severe

dB

Partition Duty Rating (BS 5234):

4600mm

Maximum Recommended Partition height: (Based on limiting deflection of L/240@200Pa) Partition nominal thickness (excluding finishes):

122mm

Framing components Gypframe metal stud reference:

Gypframe 70S50 ‘C’ Studs

600mm

Stud centres:

Gypframe 72C50 Floor & Ceiling Channel for partitions up to 4199mm, Gypframe 72DC60 Deep Floor & Ceiling Channel on partitions 4200mm – 4600mm Gyproc Sealant applied around perimeter to both sides of partition framework

Gypframe channel reference:

Acoustical sealant:

Deflection Head requirement:

As per structural requirements (defined by others)

Drawing references:

Refer to relevant Architects drawings

Plasterboard components Number of plasterboard layers each side:

2

12.5mm Gyproc SoundBloc 12.5mm Gyproc SoundBloc

Gyproc plasterboards:

Layer 1 (Inner):

Layer 2 Layer 3

n/a

25mm Gyproc Drywall Screws 38mm Gyproc Drywall Screws

Screw fixings for boarding: Layer 1 (Inner):

Layer 2 Layer 3

n/a  All board joints installed staggered in accordance with Gyproc’s current installation recommendations.  Vertical Joints in face layer boards treated in accordance with Gyproc Paper Joint Tape method.