combustible floor. Position the furnace as close to the chimney as possible. Air for combustion must be provided into the room where the furnace is located. Allow air free access to the furnace for combustion and ventilation. RECOMMENDATION: Purchase Chimfex™ Dry Chemical Chimney Fire Extinguisher. These are readily available at most stove shops and hardware stores. Smoke detectors should be installed on all levels of your building . Having a fire extinguisher in the furnace room or area is strongly recommended.

OPEN/CLOSE RETURN DAMPERS 3 PLACES

RETURN AIR DUCT

SUPPLY DUCT

BACK DRAFT DAMPERS

Assembly of Unit Please review the parts list and diagrams contained on pages 15 - 17 of this manual.

DOUBLE CHECK TO MAKE SURE YOU HAVE RECEIVED ALL THE REQUIRED COMPONENTS. IF YOU FIND THAT THERE IS A PART MISSING, CALL 1-800-875-4788 FOR FASTEST SERVICE, PLEASE DO NOT GO BACK TO THE DEALER. DEALER DOES NOT CARRY REPLACEMENT PARTS. NOTE: For your convenience your IGNITECH Furnace has been factory assembled and the electrical control assembly pre-wired.

1. Fasten the right and left side angle brackets to the circulation blower using (4) ¼ - 20 bolts and nuts. Line up the blower with the pre-drilled holes on the backside of the furnace, firmly attach with the screws provided.

2. Attach blower to the left and right mounting brackets.

1/4-20 Bolt Four Places 1/4 - 20 Bolt

Angle Bracket Angle Bracket

1/4-20 Nut 1/4 - 20 Nut

Blower Assembly Blower Assembly Blower Assembly

Mounting Screw Mou ting Screw Mounting Screw

4