TESCO Catalog 2025

Catalog No. FTS-2990 TESCO Meter Field Test Station

As the industry standard in meter accuracy and functional testing in a small, convenient package, the TESCO DTS-2990 is now available in a portable configuration to help solve the challenges of testing meters at the meter site. The new FTS-2990 maintains the same proven reliability and accuracy for testing both self- contained and transformer-rated meters as the standard DTS- 2990, but is now available with a rugged case, making it ideal for meter testing in any location. The FTS-2990 is a fully ANSI-compliant test board, providing comprehensive testing for meters across a wide range of conditions. Its new waveform generator aligns with ANSI C12.20-2015 (pub 4/2017) standards, incorporating all specified waveforms. This system accommodates testing for solid-state meters with a capacity extending up to 50 amps. Utilizing a single voltage and three isolated current sources, the FTS-2990 ensures thorough and precise testing for an array of meters.

METER FIELD TEST STATION CATALOG NO. FTS-2990 Specifications and Features: • Digital Waveform Generator • Voltage Drive: 30-350V RMS, 606V PK (line to neutral) • Current Drive: 0.01A to 50A RMS, 75A PK • Arbitrary harmonically defined waveforms • Automatic Generation of all ANSI C12.20-2015 waveforms • True zero insertion force socket with automatic closure on meter insertion • Powerful multi-core, 32 bit processors • 7” high resolution screen • Direct sunlight readable Protected screen • Integrated control keypad • Ethernet connectivity • USB-A & USB-B • DB9 • Phase fully adjustable as phase or power factor • Voltage Setting Accuracy: ± 1.0% • Current Setting Accuracy: ± 1.0% • Fundamental Frequency: 45-65 Hz • Built in, one voltage, three current reference standard traceable back to NIST Measurement Accuracy • • • • • • • • •

Voltage: ± 0.02% Current: ± 0.02% Watts: ± 0.04%, ± 0.02% typical VA: ± 0.04%, ± 0.02% typical VAR: ± 0.04%, ± 0.02% typical WHrs: ± 0.04%, ± 0.02% typical VAHrs: ± 0.04%, ± 0.02% typical VARHrs: ± 0.04%, ± 0.02% typical

• Valid for 50 or 60 Hz and currents from 0.2 to 50A • Simultaneous time and frequency domain measurements • All ANSI (12.20-2015pub4/2017) Meter Forms except 7S • Demand and time-run test capabilities waveforms • Dropped cycle testing on request • 1037-DTS Optical P/U •

Computer control software package to enable full control of the board and test data storage via external PC Measurements: 21.2” x 16.0” x 10.6” at approximately 55 lbs. Power requirements: 120-480V AC, 1PH, 2A to 1/2A

TESCO Metering 925 Canal Street · Bristol, PA 19007 · Phone: 215.228.0500 tescometering.com

52