2022 Marine Catalog

BlueCool C-Series Ultra Compact Chiller

Technical data

BlueCool C-Series

Type

C16 M C20 M C27 M C32 T

C40 T

C55 T

C81 R

C108 Q

Part numbers

WBCL1205001 WBCL1205002 WBCL1205003 WBCL1207001 WBCL1207002 WBCL1207003 WBCL1207004 WBCL1207005

Cooling capacity* (BTU / h)

16,000

20,000

27,000

32,000

40,000

55,000

81,000

108,000

Cooling capacity* (kW)

4.7

5.9

7.9

9.4

11.7

16.1

23.7

31.7

Heating via reverse cycle integ- rated

yes

yes

yes

yes

yes

yes

yes

yes

Voltage (V)

230 (-15%/ +10%)

230 (-15%/ +10%)

230 (-15%/ +10%)

230 (-15%/ +10%)

230 (-15%/ +10%)

230 (-15%/ +10%)

230 (-15%/ +10%)

230 (-15%/ +10%)

Frequency ++ (Hz)

50 / 60 (+-5%)

50 / 60 (+-5%)

50 / 60 (+-5%)

50 / 60 (+-5%)

50 / 60 (+-5%)

50 / 60 (+-5%)

50 / 60 (+-5%)

50 / 60 (+-5%)

Current draw running** (A)

4.4 – 6.0

6.9 – 8.0

8.6 – 9.2

8.8 – 12.0 13.8 – 16.0 17.2 – 18.4 25.8 – 27.6 34.4 – 36.8

Current draw Start max. peak (A) 50 Hz

54

60

77

60

68

87

97

107

Current draw RMS40**** (A) 50 Hz

35

39

49

41

47

59

69

79

Current draw RMS300*** (A) 50 Hz

19

20

32

25

28

42

52

62

Current draw Start max. peak with Soft Start (A) 50 Hz Current draw RMS40**** with Soft Start (A) 50 Hz Current draw RMS300 with Soft Start (A) 50 Hz Locked Rotor Amperage LRA (A) (comp. only)

22

22

34

28

30

44

54

64

12

14

18

18

22

28

38

48

9

10

17

15

18

27

37

47

37

43

54

37

43

54

54

54

Max. circuit breaker (A)

16

16

20

2 x 16

2 x 16

2 x 20

3 x 20

4 x 20

Chilled water connection (mm) Chilled water connection (inch)

25 1

25 1

25 1

25 1

25 1

25 1

32 1 1/4

– 1 1/4 F BST

Minimal chilled water flow (l /min.)

13

16

19

26

32

38

57

76

Recommended chilled water pump

WB500

WB500

WB1000

WB1000

WB1500

WB1500

WB2000

WB3500

Seawater connection (mm) Seawater connection (inch) Minimal seawater flow at 50 Hz (l /min.) Minimal seawater flow at 60 Hz (l /min.)

19 3/4

19 3/4

19 3/4

19 3/4

25 1

25 1

32 1 1/4

– 1 1/4 F BST

14

17

21

28

34

42

63

84

17

20

25

34

41

50

75

100

Recommended seawater pump

WB500 / WB500G

WB500 / WB500G

WB1000

WB1000

WB1500 / WB1000G

WB1500 / WB2000

WB2000 / WB2500G

WB3000G

Dimensions L x W x H (mm) Dimensions L x W x H (inch)

390 x 290 x 355 15.4 x 11.4 x 14.0

440 x 330 x 360 17.3 x 13.0 x 14.0

440 x 330 x 395 17.3 x 13.0 x 15.6

590 x 410 x 500 23.2 x 16.1 x 19.7

590 x 410 x 500 23.2 x 16.1 x 19.7

590 x 410 x 550 23.2 x 16.1 x 21.7

870 x 430 x 575 33.5 x 16.9 x 22.6

860 x 640 x 600 33.9 x 22.4 x 23.6

Schematics C16-27M

Weight (kg)

34

37

45

65

70

86

119

173

Min. sea water temp. Heating (°C)

6

6

6

6

6

6

6

6

Max. sea water temp. Cooling (°C)

35

35

35

35

35

35

35

35

General note: Values in this table given for 50 Hz only. 60 Hz data available on request. * BTU / h are based on 7 °C evaporating temperature and 38 °C condensing temperature ** Amperage values for core unit depend on compressor load. Max values at tropical conditions at 230 V / 50 Hz *** Starting amperage RMS (Root Mean Square) for core unit for first 300 ms **** Starting amperage RMS (Root Mean Square) for core unit for first 40 ms + Recommendation only. Pump size shall be adapted to application constraints in order to always ensure minimal sea water flow. ++ BlueCool C-Series systems are tested and approved by Webasto for 50 / 60 Hz operation

H

D W

L

Mono C16 M – C27 M

146

24.10.2012

Schematics S- und C-Series

5

Made with FlippingBook Online newsletter