BlueCool P-Series Professional Chiller Series
BlueCool P-Series Triple chiller
Type
P126 R
P144 R
P180 R
P216 R
P252 R
Cooling capacity* (BTU/h)
126,000
144,000
180,000
216,000
252,000
Cooling capacity* (kW)
37
42.2
52.8
63.3
73.8
Frequency (Hz)
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
Current draw running** (A) for 230 V 1-phase
28
37
–
–
–
Current draw running** (A) for 400 V 3-phase
12
15
18
20
25
Current draw running** (A) for 208 V 3-phase
21
26
50
38
72
Current draw running FLA **** (A) for 230 V 1-phase Current draw running FLA **** (A) for 400 V 3-phase Current draw running FLA **** (A) for 208 V 3-phase Locked Rotor Amperage LRA (A) for Single compressor 230 V 1-phase Locked Rotor Amperage LRA (A) for Single compressor 400 V 3-phase Locked Rotor Amperage LRA (A) for Single compressor 208 V 3-phase
69
71
–
–
–
21
30
33
36.3
45
40
56
75
81
76
100
114
–
–
–
46
50
59
74
101
95
98
139
172
179
Min. chilled water flow (l /min.)
104
115
138
158
180
Min. seawater flow (l /min.)
82
92
106
125
145
Recommended seawater pump+
WB3000G WB3500
WB3000G WB3500
WB5500
WB5500
WB5500
Dimensions (L x W x H) (mm)
640 x 1,250 x 765 640 x 1,250 x 765 640 x 1,250 x 765 640 x 1,250 x 840 640 x 1,250 x 840
Dimensions (L x W x H) (inch)
25.2 x 49.2 x 30.1 25.2 x 49.2 x 30.1 25.2 x 49.2 x 30.1 25.2 x 49.2 x 33.1 25.2 x 49.2 x 33.1
Dimensions (L x W x H) (mm) tropical
640 x 1,250 x 765 640 x 1,250 x 765 640 x 1,250 x 840 640 x 1,250 x 840 640 x 1,250 x 840
Dimensions (L x W x H) (inch) tropical
25.2 x 49.2 x 30.1 25.2 x 49.2 x 30.1 25.2 x 49.2 x 33.1 25.2 x 49.2 x 33.1 25.2 x 49.2 x 33.1
Weight (kg)
180
190
210
250
260
Available options 230 V / 1-phase
–
–
–
c
c
208 V / 3-phase
c
c
c
c
c
Reverse Cycle Heating
g
g
g
g
g
Cool Only version
c
c
c
c
c
Tropicalized version
c
g
c
g
c
Soft Start 400 V / 230 V / 208 V
c / c / –
c / – / –
c / – / –
c / – / –
c / – / –
Upgrade box /MCA Box
c
c
c
c
c
Silent Block
c
c
c
c
c
General note: Values in this table given for 50 Hz only. 60 Hz data available on request. * BTU / h are based on 7 °C evaporating temperature and 38 °C condensing temperature. ** Amperage values for core unit at nominal conditions at 50 Hz. **** FLA (Full Load Amperage) is the current draw at maximum conditions. + Recommendation only. Pump size shall be adapted to application constraints in order to always ensure minimal sea water flow. ++ BlueCool P-Series systems are tested and approved by Webasto for 50 / 60 Hz operation.
g Standard
c Optional – Not available
154
Made with FlippingBook Online newsletter