BlueComfort Premium DeLuxe Integration
The DeLuxe integration has all the features of the Basic integration but additionally allows the integration of a water boiler as well as further fan blowers or radiators into the system. It therefore provides the highest comfort in heating and sanitary water supply. The mixing valve limits the water temperature in the A/C loop to 60 °C. A summer / winter switch allows heating of the boiler in summer while the A/C system is cooling the cabins at the same time.
C
I
B
D
G
E
A
H
F
B A
Water heater
Produces hot (approx. 80°C) water when system switches to heating
Water pump
Circulates the water
C
A/C chiller unit
Cools down the water when system switches to cooling
D
Chiller control
Controls the complete A/C system and the water heater Starts the compressor when cooling is necessary Starts the heater when heating is necessary
F E
Air handler
Warms up or cools down returning air
3-way valve
Switches between cooling or heating loop
G H
Water boiler
Heats up the sanitary water
Blowers or radiators can optionally be used in areas with extra high heating demand (e. g. windscreen for demisting)
I
Summer/ Winter switch
Allows separate boiler operation in summer mode
For a perfect integration Webasto recommends Isotemp double coil boilers. For more Information visit: indelwebastomarine.com
203