Safety training

Control of Hazardous Energies Standard / V5 DRAFT REVIEW - Oct 2025

The electrical system should contain at least:

A 12 V battery

Electrical protection

Appropriate electrical wires

Switches

Capacitors

Terminals for rail

Push buttons (NO and NC)

1 contactor or relays for each load

Any equipment used during this GWO training module shall meet or exceed the minimum requirements of the national standards in the country where the training is taking place. When working in a country where there is no applicable national standard then the equipment shall meet or exceed the minimum requirements of the European standards.

2.

CoHE Pressure Fluid Safety module

The following equipment is required during the entire duration of this pressure fluid safety module to meet the need of the pressure fluid safety module: • PPE suitable for pressure fluids tasks (gloves, safety goggles, safety shoes or boots and suitable clothing or overalls)

Pressure gauge/manometer

Lockout-Tagout equipment. As a minimum:

o 6 x padlocks o 6 x caution notices / tags

An example of accessories for locking certain components e.g., valve

A pressure fluid system which as a minimum must be able to:

Build pressure

Release pressure

Measure pressure (test points)

Store pressure even with pumps stopped

Global Wind Organisation ©2025 / www.globalwindsafety.org