Clean Air Industries Brahm Collector Series User Manual

BRAHM TM BC Central Collector Series

(1) Valve DIN connector: The cables will have the DIN connectors already molded on the end. Place the connector onto the valve coil and use the screw on the connector to secure it to the coil. (1) Compressed Air Connection: A compression fitting is already installed on the valve. Simply push the black tubing into the compression fitting. The fitting will automatically clamp down onto the tubing. The tubing should be preinstalled into the wire track on top of the unit. The compressed air plenum must be built on the outside of the units. Each module must have a compressed air connection. See pictures. The last unit uses a 90 degree elbow. The first and intermediate units will use tee branches. The connection between is made with hose nipples and 1” pneumatic hose. Hose clamps must be installed to fasten and secure the hose.

For all units (even single module): There a small ¼” compressed air line that tees off the incoming compressed air line. There is a compression fitting pre installed on the unit. Simply push the black tubing into the compression fitting. The fitting will automatically clamp down onto the tubing. The tubing should be preinstalled into the wire track on top of the unit. An air regulator is provided. It must be screwed onto the incoming air line to the unit and set to 80-100 psi. 100 psi is recommended.